Influence of Crown-to-Implant Ratio on Stress Around Single Short-Wide Implants: A Photoelastic Stress Analysis

Texto completo
Autor(es):
Sotto-Maior, Bruno Salles [1] ; Senna, Plinio Mendes [2] ; da Silva-Neto, Joao Paulo [3] ; de Arruda Nobilo, Mauro Antonio [3] ; Del Bel Cury, Altair Antoninha [3]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Sao Leopoldo Mand Dent Sch, Dept Implantol, Campinas, SP - Brazil
[2] Unigranrio Univ, Hlth Sci Ctr, Duque De Caxias - Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Piracicaba - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY; v. 24, n. 1, p. 52-56, JAN 2015.
Citações Web of Science: 9
Resumo

Purpose: The aim of this study was to evaluate the photoelastic fringe patterns around two short-wide implants supporting single crowns with different crown-to-implant (C/I) ratios. Materials and Methods: External hexagon (EH) cylindrical implants (5 x 7 mm) or Morse Taper (MT) conical implants (5 x 6 mm) were embedded individually into photoelastic resin blocks. Each implant received a single metal-ceramic crown, with a C/I ratio of 1: 1 or 2: 1 (n = 10). Each set was positioned in a polariscope and submitted to a 0.5 kgf compressive load, applied axially or obliquely (30 degrees). The polariscope images were digitally recorded, and based on isoclinal and isochromatic fringes, the shear stress was calculated at 5 predetermined points around each implant. Data were analyzed by two-way ANOVA (alpha = 0.05). Results: Under axial loading, the stress was concentrated at the crestal region, and there were no differences between C/I ratio or implant types. In contrast, under oblique loading, EH implants showed lower stress values than the MT group and the 2: 1 C/I ratio showed higher stress concentration for both implant types (p < 0.05). Moreover, MT implants showed stress distribution through a higher area than the EH implant did, with a tendency to direct the stress toward the implant's apex under oblique loading. Conclusion: MT conical short-wide implants showed higher stress values that were distributed through a higher area directed to the implant apex. The C/I ratio influences the stress distribution only under oblique loading. (AU)

Processo FAPESP: 09/14982-4 - Comportamento biomecânico de diferentes proporções coroa/implante na interface de implantes osseointegrados - estudo comparativo com elemento finito tridimensional
Beneficiário:Bruno Salles Sotto Maior
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 08/05123-5 - Análise fotoelástica da distribuição de tensões e resistência mecânica de infra-estruturas metálicas sobre implantes após soldagem Laser ou TIG
Beneficiário:Mauro Antonio de Arruda Nóbilo
Modalidade de apoio: Auxílio à Pesquisa - Regular