Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Stress distribution in delayed replanted teeth splinted with different orthodontic wires: a three-dimensional finite element analysis

Texto completo
Autor(es):
de Souza, Fernando Isquierdo [1] ; Poi, Wilson Roberto [2] ; da Silva, Vanessa Ferreira [2] ; Martini, Ana Paula [1] ; da Cunha Melo, Regis Alexandre [1] ; Panzarini, Sonia Regina [2] ; Rocha, Eduardo Passos [1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Estadual Paulista, UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Aracatuba, SP - Brazil
[2] Univ Estadual Paulista, UNESP, Aracatuba Dent Sch, Dept Surg & Integrated Clin, BR-16015050 Aracatuba, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: DENTAL TRAUMATOLOGY; v. 31, n. 3, p. 190-195, JUN 2015.
Citações Web of Science: 1
Resumo

AimThe aim was to evaluate the biomechanical behavior of the supporting bony structures of replanted teeth and the periodontal ligament (PDL) of adjacent teeth when orthodontic wires with different mechanical properties are applied, with three-dimensional finite element analysis. Materials and methodsBased on tomographic and microtomographic data, a three-dimensional model of the anterior maxilla with the corresponding teeth (tooth 13-tooth 23) was generated to simulate avulsion and replantation of the tooth 21. The teeth were splinted with orthodontic wire (O 0.8mm) and composite resin. The elastic modulus of the three orthodontic wires used, that is, steel wire (FA), titanium-molybdenum wire (FTM), and nitinol wire (FN) were 200 GPa, 84 GPa, and 52 GPa, respectively. An oblique load (100N) was applied at an angle of 45 degrees on the incisal edge of the replanted tooth and was analyzed using Ansys Workbench software. The maximum (sigma(max)) and minimum (sigma(min)) principal stresses generated in the PDL, cortical and alveolar bones, and the modified von Mises (sigma(vM)) values for the orthodontic wires were obtained. ResultsWith regard to the cortical bone and PDL, the highest sigma(min) and sigma(max) values for FTM, FN, and FA were checked. With regard to the alveolar bone, sigma(max) and sigma(min) values were highest for FA, followed by FTM and FN. The sigma(vM) values of the orthodontic wires followed the order of rigidity of the alloys, that is, FA>FTM>FN. ConclusionThe biomechanical behavior of the analyzed structures with regard to all the three patterns of flexibility was similar. (AU)

Processo FAPESP: 08/00209-9 - Comportamento biomecânico de uma prótese parcial removível classe I mandibular suportada distalmente por um implante osseointegrado: análise tridimensional de elementos finitos
Beneficiário:Eduardo Passos Rocha
Modalidade de apoio: Auxílio à Pesquisa - Regular