Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Digital vertebral morphometry performed by DXA: a valuable opportunity for identifying fractures during bone mass assessment

Texto completo
Autor(es):
Muszkat, Patricia [1] ; Rodrigues Camargo, Marilia Brasilio [1] ; Emo Peters, Barbara Santarosa [2] ; Kunii, Ilda Sizue [1] ; Lazaretti-Castro, Marise [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Fed Univ Sao Paulo Unifesp, Sch Med, Div Endocrinol, Sao Paulo, SP - Brazil
[2] Univ Sao Paulo, Fac Publ Hlth, Dept Nutr, Sao Paulo, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Arquivos Brasileiros de Endocrinologia e Metabologia; v. 59, n. 2, p. 98-104, APR 2015.
Citações Web of Science: 4
Resumo

Objectives: To evaluate the usefulness of vertebral morphometry in identifying unreferred vertebral fractures and correlate potential risk factors. Subjects and methods: Female patients above 45 years, postmenopausal for at least 2 years, diagnosed with osteoporosis and undergoing treatment for at least three months were considered eligible. All of them underwent bone densitometry and vertebral morphometry performed by concomitant DXA. The presence of fractures was defined between T7 and L4; only moderate and severe fractures were considered for analysis. All volunteers were submitted to laboratory tests, anthropometry and responded a questionnaire on their lifestyle habits and medical history. Results: Thirty two (17%) out of the 188 female patients presented with at least one vertebral fracture, among whom only 4 (12.5%) were previously aware of the fracture. The fractures were mainly located on the thoracic spine. Nine patients had severe fractures (28.1%), whereas 23 had moderate fractures (71.9%). On average, patients with fractures were 5 years older and weighed 5 kilograms less than those without fractures. The creatinine clearance was on average 9 mL/min less in patients with vertebral fracture. The assessment of vertebral fractures by morphometry is a fast, accurate and complementary method associated with low radiation exposure for identifying moderate and severe vertebral fractures. Predisposition to vertebral fractures does not depend solely on BMD. (AU)

Processo FAPESP: 08/55567-7 - Status da vitamina D em portadores de Osteoporose tratados no ambulatório de doenças osteometabólicas de um Hospital Universitário na Cidade de São Paulo e avaliação da absorção intestinal de cálcio
Beneficiário:Marise Lazaretti Castro
Modalidade de apoio: Auxílio à Pesquisa - Regular