Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Running-based Anaerobic Sprint Test as a Procedure to Evaluate Anaerobic Power

Texto completo
Autor(es):
Andrade, V. L. [1, 2] ; Zagatto, A. M. [3] ; Kalva-Filho, C. A. [1, 2] ; Mendes, O. C. [4] ; Gobatto, C. A. [5] ; Campos, E. Z. [6] ; Papoti, M. [7]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Fac Med Ribeirao Preto, Ribeirao Preto - Brazil
[2] Univ Sao Paulo, Rehabil & Funct Performance, BR-14040907 Ribeirao Preto - Brazil
[3] Sao Paulo State Univ, Dept Phys Educ, Bauru - Brazil
[4] Fac Integradas Bauru, Bauru - Brazil
[5] Univ Estadual Campinas, Sport Sci, Campinas, SP - Brazil
[6] Univ Estadual Paulista, UNESP, Educ Fis, Presidente Prudente - Brazil
[7] Univ Sao Paulo, Sch Phys Educ & Sport Ribeirao Preto, BR-14040907 Ribeirao Preto - Brazil
Número total de Afiliações: 7
Tipo de documento: Artigo Científico
Fonte: INTERNATIONAL JOURNAL OF SPORTS MEDICINE; v. 36, n. 14, p. 1156-1162, DEC 2015.
Citações Web of Science: 12
Resumo

The aim of this study was to evaluate the use of the running anaerobic sprint test (RAST) as a predictor of anaerobic capacity, compare it to the maximal accumulated oxygen deficit (MAOD) and to compare the RAST's parameters with the parameters of 30-s all-out tethered running on a treadmill. 39 (17.0+/-1.4 years) soccer players participated in this study. The participants underwent an incremental test, 10 submaximal efforts {[}50-95% of velocity correspondent to VO2MAX (vVO(2MAX))] and one supramaximal effort at 110% of vVO2MAX for the determination of MAOD. Furthermore, the athletes performed the RAST. In the second stage the 30-s all-out tethered running was performed on a treadmill (30-s all-out), and compared with RAST. No significant correlation was observed between MAOD and RAST parameters. However, significant correlations were found between the power of the fifth effort (P5) of RAST with peak and mean power of 30-s all-out (r = 0.73 and 0.50; p < 0.05, respectively). In conclusion, the parameters from RAST do not have an association with MAOD, suggesting that this method should not be used to evaluate anaerobic capacity. Although the correlations between RAST parameters with 30-s all-out do reinforce the RAST as an evaluation method of anaerobic metabolism, such as anaerobic power. (AU)

Processo FAPESP: 10/08761-2 - Validade do "anaerobic running sprint test (rast)" como ferramenta preditora da capacidade anaeróbia em jogadores de futebol
Beneficiário:Vitor Luiz de Andrade
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica