Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Validation of an UV spectrophotometric assay for the quantification of polymyxin B in solid lipid nanoparticles

Texto completo
Autor(es):
Severino, P. [1, 2, 3] ; Silveira, E. F. [2, 3] ; Vazzana, M. [4] ; Chaud, M. V. [5] ; Santana, M. H. A. [1] ; Souto, E. B. [6, 7, 8]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] State Univ Campinas UNICAMP, Sch Chem Engn, Biotechnol Proc Dev Lab, Campinas, SP - Brazil
[2] Univ Tiradentes Unit, Lab Nanotechnol & Nanomed LNMed, Aracaju - Brazil
[3] Inst Technol & Res ITP, Aracaju - Brazil
[4] Univ Messina, Dept Biol & Environm Sci, Messina - Italy
[5] Univ Sorocaba, Lab Biomat & Nanotechnol Dev & Evaluat Bioact Sub, Sao Paulo - Brazil
[6] Univ Coimbra, Fac Pharm, Dept Pharmaceut Technol, P-3000548 Coimbra - Portugal
[7] Univ Coimbra, Ctr Neurosci & Cell Biol, P-3000548 Coimbra - Portugal
[8] Univ Coimbra, Inst Biomed Imaging & Life Sci CNC IBILI, P-3000548 Coimbra - Portugal
Número total de Afiliações: 8
Tipo de documento: Artigo Científico
Fonte: Pharmazie; v. 70, n. 11, p. 693-697, NOV 2015.
Citações Web of Science: 1
Resumo

Polymyxins are efficient antibiotic drugs used for the treatment of Gram-negative bacterial infections. These compounds are not absorbed in the gastrointestinal tract and are responsible for serious toxicological effects. In order to enhance their therapeutic effectiveness, decrease the adverse/toxic side effects and promote a sustained release profile, a derivative-polymyxin B sulphate-has been formulated in solid lipid nanoparticles (SLNs) intended for buccal administration. To quantify polymyxin B in the formulation, UV spectrophotometry analysis was applied, validating the analytical methodology by assessing the selectivity, accuracy, precision, linearity, and repeatability. Analyses were performed at 210nm keeping the samples at 25. degrees C. Results showed that lipid composition of SLNs did not interfere with the polymyxin B spectra. The linearity showed a correlation coefficient of 0.9977 in the range of 5-90 mu g/mL. Quantification of polymyxin B by UV spectrophotometry, at 210nm in SLN formulations, was approved in all analyzed parameters, validating the methodology proposed in this work. (AU)

Processo FAPESP: 11/20801-2 - Encapsulação de polimixina B em NLS para incorporação em hidrogéis mucoadesivos para tratamento de mucosite oral
Beneficiário:Patricia Severino
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado