Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Determination of europium isotope ratios in natural waters by MC-ICP-MS

Texto completo
Autor(es):
Arantes de Carvalho, Gabriel Gustinelli ; Oliveira, Pedro Vitoriano ; Yang, Lu
Número total de Autores: 3
Tipo de documento: Artigo Científico
Fonte: Journal of Analytical Atomic Spectrometry; v. 32, n. 5, p. 987-995, MAY 1 2017.
Citações Web of Science: 8
Resumo

An analytical protocol for the accurate and precise determination of the europium isotope ratio in low level natural waters is presented for the first time by using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Parameters affecting the separation of Eu from the matrix by employing a single-step column separation with di(2-ethylhexyl) orthophosphoric acid (HDEHP) resin were investigated in detail. Matrix elements (e.g., alkali, alkali-earth and transition metals) were efficiently removed and Eu was quantitatively separated from other rare earth elements (REEs) by sequential elution using gradient HCl concentrations (from 0.25 to 0.75 mol L-1). Fractionation of Eu isotopes in the column was not observed, since quantitative europium recovery (101.2 +/- 0.5% mean and 1 SD, n = 3) was obtained (data based on 150 mL SLRS-6 river water CRM test portions spiked with 1.0 ng mL(-1) Eu standard solution). A combined standard-sample bracketing with internal normalization method was employed for the mass bias correction, wherein Gd was added to both the sample and standard as an internal standard. The developed method was validated by processing 0.02 ng mL(-1) Eu spiked river water CRM SLRS-6 (wherein Eu was removed first by using the above-mentioned column separation method) using the proposed method, and satisfying results (delta Eu-151/153 value of 0.01 +/- 0.02 parts per thousand; 1 SD) relative to Eu standard solution were obtained. No significant differences were found in the delta Eu-151/153 values in river water SLRS-6, drinking water AQUA-1 and collected groundwater samples from Brazil, which ranged from -0.07 +/- 0.02 to 0.12 +/- 0.24 (mean +/- 1 SD, n = 5). (AU)

Processo FAPESP: 15/06161-1 - Emprego de substratos poliméricos para separação e concentração de elementos terras raras de águas
Beneficiário:Gabriel Gustinelli Arantes de Carvalho
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 15/25094-3 - Análise isotópica de águas subterrâneas por espectrometria de massas com plasma acoplado indutivamente
Beneficiário:Gabriel Gustinelli Arantes de Carvalho
Modalidade de apoio: Bolsas no Exterior - Estágio de Pesquisa - Pós-Doutorado