Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis

Texto completo
Autor(es):
Silva, Bruno C. ; Santos, Roberto S. S. ; Drager, Luciano F. ; Coelho, Fernando M. ; Elias, Rosilene M.
Número total de Autores: 5
Tipo de documento: Artigo Científico
Fonte: FRONTIERS IN MEDICINE; v. 4, MAY 19 2017.
Citações Web of Science: 4
Resumo

Introduction: Obstructive sleep apnea (OSA) is common in edematous states, notably in hemodialysis patients. In this population, overnight fluid shift can play an important role on the pathogenesis of OSA. The effect of compression stockings (CS) and continuous positive airway pressure (CPAP) on fluid shift is barely known. We compared the effects of CS and CPAP on fluid dynamics in a sample of patients with OSA in hemodialysis, through a randomized crossover study. Methods: Each participant performed polysomnography (PSG) at baseline, during CPAP titration, and after 1 week of wearing CS. Neck circumference (NC) and segmental bioelectrical impedance were done before and after PSG. Results: Fourteen patients were studied (53 9 years; 57% men; body mass index 29.7 6.8 kg/m(2)). Apnea hypopnea index (AHI) decreased from 20.8 (14.2; 39.6) at baseline to 7.9 (2.8; 25.4) during CPAP titration and to 16.7 (3.5; 28.9) events/h after wearing CS (CPAP vs. baseline, p = 0.004; CS vs. baseline, p = 0.017; and CPAP vs. CS, p = 0.017). Nocturnal intracellular trunk water was higher after wearing CS in comparison to baseline and CPAP (p = 0.03). CS reduced the fluid accumulated in lower limbs during the day, although not significantly. Overnight fluid shift at baseline, CPAP, and CS was -183 +/- 72, 343 +/- 220, and 290 +/- 213 ml, respectively (p = 0.006). Overnight NC increased at baseline (0.7 +/- 0.4 cm), decreased after CPAP (-1.0 +/- 0.4 cm), and while wearing CS (-0.4 +/- 0.8 cm) (CPAP vs. baseline, p < 0.0001; CS vs. baseline, p = 0.001; CPAP vs. CS, p = 0.01). Conclusion: CS reduced AHI by avoiding fluid retention in the legs, favoring accumulation of water in the intracellular component of the trunk, thus avoiding fluid shift to reach the neck. CPAP improved OSA by exerting local pressure on upper airway, with no impact on fluid redistribution. CPAP performed significantly better than CS for both reduction of AHI and overnight reduction of NC. Complementary studies are needed to elucidate the mechanisms by which CPAP and CS reduce NC. (AU)

Processo FAPESP: 12/05236-0 - Alterações objetivas do sono pré e pós paratireoidectomia total em pacientes com hiperparatireoidismo secundário em hemodiálise
Beneficiário:Rosilene Motta Elias Coelho
Modalidade de apoio: Auxílio à Pesquisa - Regular