Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Energy Ratio (E-R) for the Standard Penetration Test Based on Measured Field Tests

Texto completo
Autor(es):
Lukiantchuki, J. A. [1] ; Bernardes, G. P. [2] ; Esquivel, E. R. [3]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] Univ Estadual Maringa, Dept Engn Civil, Maringa, Parana - Brazil
[2] Univ Estadual Paulista, Dept Engn Civil, Guaratingueta, SP - Brazil
[3] Univ Sao Paulo, Dept Geotecnia, Sao Carlos, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: SOILS AND ROCKS; v. 40, n. 2, p. 77-91, MAY-AUG 2017.
Citações Web of Science: 0
Resumo

The Standard Penetration Test (SPT) is often used to estimate the soil parameters for geotechnical design projects, using the N SPT index. However, these estimates are performed based on empirical correlations without any scientific basis. Moreover, the test has a large inherent results dispersion due to the use of different types of equipment and execution procedures. Since the N SPT index depends on the amount of energy that is effectively transmitted to the sampler during the hammer fall, it is fundamental to be able to estimate this energy. Given the importance of estimating the energy that reaches the SPT sampler, an instrumented subassembly was developed in order to simultaneously assess the amount of energy transmitted to the drill rods, at sections just above the sampler and just below the anvil. This paper presents a series of SPT experimental results carried out in two different sites located in the State of Sao Paulo, using two different equipment set-ups (with manual and automatic tripping mechanisms), enabling the assessment of the top and bottom energy ratio under different conditions. Results show that for hand lifting hammer and automatic trip hammer systems the difference in the energy ratio is not significant. However, the dispersion of the results for the hand lifting hammer system is more pronounced due to execution procedures, equipment and operators. (AU)

Processo FAPESP: 08/08268-4 - Interpretação de resultados de ensaios SPT com base em energia
Beneficiário:Edmundo Rogério Esquivel
Modalidade de apoio: Auxílio à Pesquisa - Regular