Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Carbon black supported Au-Pd core-shell nanoparticles within a dihexadecylphosphate film for the development of hydrazine electrochemical sensor

Texto completo
Autor(es):
Deroco, Patricia B. [1] ; Melo, Iasmim G. [2] ; Silva, Lays S. R. [2] ; Eguiluz, Katlin I. B. [2] ; Salazar-Banda, Giancarlo R. [2] ; Fatibello-Filho, Orlando [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Fed Sao Carlos, Dept Chem, POB 676, BR-13560970 Sao Carlos, SP - Brazil
[2] Univ Tiradentes, PEP, Res & Technol Inst, Electrochem & Nanotechnol Lab, BR-49032490 Aracaju, SE - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: SENSORS AND ACTUATORS B-CHEMICAL; v. 256, p. 535-542, MAR 2018.
Citações Web of Science: 18
Resumo

An amperometric method for the determination of hydrazine (HDZ) using a glassy carbon (GC) electrode modified with carbon black supported Au-Pd core-shell structured nanoparticles (Au@Pd/CB) within dihexadecylphosphate (DHP) film (Au@Pd/CB-DHP/GCE) is proposed. Au@Pd nanoparticles were synthesized by chemical reduction of AuCl3 and PdCl2 using ethylene glycol as a reducing agent, and the nanoparticles supported on CB were characterized by scanning electron microscopy, transmission electron microscopy, energy dispersive X-ray spectroscopy and X-ray diffraction techniques. The proposed Au@Pd/CB-DHP/GCE and CB-DHP/GCE (without Au@Pd) electrodes were used to investigate the electrochemical behavior of HDZ using cyclic voltammetry. When the Au@Pd/CB-DHP/GCE was used, an electrocatalytic effect was observed, the analytical signal was substantially increased (87%) and the oxidation potential decreased, i.e. in 728 mV. Additionally, the apparently heterogeneous electron transfer rate constant (k(0)) obtained for the Au@Pd/CB-DHP/GCE (0.15 cm s(-1)) was about two orders of magnitude greater than that obtained using the CB-DHP/GCE (0.068 cm s(-1)). Under the optimized conditions for the amperometric technique, a linear analytical curve for HDZ was obtained in the range of 2.50-88.0 mu mol L-1, with a limit of detection of 0.23 mu mol L-1 (0.0074 ppm). The proposed method was satisfactorily applied to determine the concentration of HDZ in natural lake and tap water samples. (C) 2017 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 14/07919-2 - Preparação de eletrodos com novos materiais à base de carbono para aplicações em eletroanalítica
Beneficiário:Patrícia Batista Deroco
Modalidade de apoio: Bolsas no Brasil - Doutorado