Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Fault Identification in the Stator Winding of Induction Motors Using PCA with Artificial Neural Networks

Texto completo
Autor(es):
Cunha Palacios, Rodrigo Henrique [1, 2, 3] ; Goedtel, Alessandro [2, 3] ; Godoy, Wagner Fontes [1, 2, 3] ; Fabri, Jose Augusto [2, 3]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sao Carlos Sch Engn, Dept Elect Engn, Ave Trabalhador Sao Carlense 400, BR-13566590 Sao Carlos, SP - Brazil
[2] Fed Technol Univ Parana, Dept Comp Engn, Ave Alberto Carazzai 1640, BR-86300000 Cornelio Procopio, PR - Brazil
[3] Fed Technol Univ Parana, Dept Elect Engn, Ave Alberto Carazzai 1640, BR-86300000 Cornelio Procopio, PR - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS; v. 27, n. 4, p. 406-418, AUG 2016.
Citações Web of Science: 7
Resumo

Three-phase induction motors are the main element of electrical into mechanical energy conversion applied in the industries. Due to its constant usage, added to adversities such as thermal, electrical and mechanical, these motors can be damaged causing unexpected process losses. Among the drawbacks of occurrences commonly presented for this equipment, approximately 37 % are related to short circuit in the stator coils. Hence, this article proposes an alternative approach for stator fault identification in induction motors through the discretization of the current signal, in the time domain, applying a variable optimization technique of principal components analysis (PCA) and artificial neural networks (ANNs) types multilayer perceptron (MLP) and radial basis function. Experimental results are presented with data gathered from an experimental workbench, considering various supply conditions and also under a wide load variation, by using the amplitude of the current signals in the time domain. Moreover, the MLP network presented the best results and the PCA technique provided a considerable reduction in the number of ANNs inputs, and in general, the classification results were comparable to the results obtained when the networks inputs considered the technique employing downsampling of 30 points to represent the current signals using half-cycle of the waveform. (AU)

Processo FAPESP: 11/17610-0 - Monitoramento e controle de sistemas dinâmicos sujeitos a falhas
Beneficiário:Roberto Kawakami Harrop Galvão
Modalidade de apoio: Auxílio à Pesquisa - Temático