Sub-minute determination of rifampicin and isoniazid in fixed dose combination tablets by capillary zone electrophoresis with ultraviolet absorption detection

Texto completo
Autor(es):
Duarte, Lucas Mattos [1] ; Amorim, Tatiane Lima [1] ; Chellini, Paula Rocha [2] ; Cantarino Adriano, Luiz Henrique [1] ; Leal de Oliveira, Marcone Augusto [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Fed Juiz de Fora, Dept Chem, GQAQ, Analyt Chem & Chemometr Grp, Juiz De Fora, MG - Brazil
[2] Univ Fed Juiz de Fora, Pharm Fac, Dept Pharmaceut Sci, Juiz De Fora, MG - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF SEPARATION SCIENCE; v. 41, n. 24, p. 4533-4543, DEC 2018.
Citações Web of Science: 4
Resumo

A validated sub minute capillary zone electrophoresis method with direct ultraviolet absorption detection for simultaneous determination of isoniazid and rifampicin in fixed-dose combination tablets was developed. Background electrolyte was defined based on the analytes effective mobility curve and it was composed by 20 mmol/L of sodium carbonate/sodium bicarbonate at pH 10.2. A careful validation procedure considering the main figures of merit was performed. Regression models were satisfactory for isoniazid and rifampicin, showing no lack of fit within 95% significance interval. Interday and intraday precision were evaluated in standard and sample and slight relative standard deviations were achieved for concentration, area, and migration time. Recovery values for accuracy in two levels were 99.97 and 90.08% for isoniazid and 95.45 and 95.12% for rifampicin. The limits of detection for isoniazid and rifampicinwere 0.22 and 0.34 mg/L, respectively, and the limits of quantification were 0.74 and 1.13 mg/L, respectively. Method selectivity was verified by injecting diluent, background electrolyte, a standard mixture, and a sample, confirming no interferent peaks. The method proved to be simple, environmentally friendly, sensitive, and was successfully applied for simultaneous quantification of isoniazid and rifampicin in fixed-dose combination tablets. (AU)

Processo FAPESP: 14/50867-3 - INCT 2014: Instituto Nacional de Ciência e Tecnologia de Bioanalítica
Beneficiário:Marco Aurelio Zezzi Arruda
Modalidade de apoio: Auxílio à Pesquisa - Temático