In Vitro Effect of Innovative Desensitizing Agents on Dentin Tubule Occlusion and Erosive Wear

Texto completo
Autor(es):
Garofalo, S. A. [1] ; Sakae, L. O. [2] ; Machado, A. C. [2] ; Cunha, S. R. [2] ; Zezell, D. M. [3] ; Scaramucci, T. [2] ; Aranha, A. C. [4]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Dept Restorat Dent, Sao Paulo - Brazil
[2] Univ Sao Paulo, Sch Dent, Dept Restorat Dent, Sao Paulo - Brazil
[3] Univ Sao Paulo, Ctr Lasers & Aplicacoes, Inst Pesquisas Energet & Nucl, Sao Paulo - Brazil
[4] Univ Sao Paulo, Dept Restorat Dent, Sch Dent, Special Lab Lasers Dent LELO, Sao Paulo - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: Operative Dentistry; v. 44, n. 2, p. 168-177, MAR-APR 2019.
Citações Web of Science: 1
Resumo

Purpose: The purpose of this study was to evaluate the effects of four in-office desensitizing products on dentin tubule occlusion and erosive wear. Methods: Dentin hypersensitivity was simulated by EDTA application for five minutes. The specimens were randomly allocated into five groups (n= 11), according to treatment: No treatment - ontrol (C), Duraphat (DUR), Desensibilize Nano P (NP), ClinPro XT Varnish (XTV), and ClinPro White Varnish (CWV). They were then submitted to erosive/abrasive cycling for five days. After EDTA, treatment, and cycling, the specimens were analyzed with an environmental scanning electron microscope (ESEM) to verify the number of opened dentin tubules (ODT) which were counted by using ImageJ software, and with a profilometer to determine the surface curvature/loss. ESEM data were analyzed with two-way repeated measure analysis of variance and Tukey tests. For the profilometer, data were analyzed with Kruskal-Wallis, Tukey, and Mann-Whitney tests. Results: After treatment, all groups showed lower ODT than the control, without significant differences between them. After cycling, the only group that showed lower ODT than the control was group XTV; however, it did not significantly differ from the other groups. For the profilometric analysis, there were significant differences in SL between the experimental times after treatment and after cycling for all groups (p<.05). After cycling, no surface loss was detected in groups DUR and XTV, which presented a significantly different curvature than group NP and the control group, but not from group CWV. Surface loss was detected for the control and groups NP and CWV, without difference among them. Conclusion: All desensitizing agents tested presented promising results concerning the obliteration of dentin tubules immediately after treatment. XTV was the only desensitizer capable of preventing the reopening of the tubules after the erosive/abrasive challenges. XTV and DUR presented a protective effect against dentin erosive wear. (AU)