Average shear rate in airlift bioreactors: searching for the true value

Texto completo
Autor(es):
Esperanca, Mateus N. [1] ; Mendes, Caroline E. [2] ; Rodriguez, Guilherme Y. [3] ; Cerri, Marcel O. [4] ; Bettega, Rodrigo [5] ; Badino, Alberto C. [5]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Fed Inst Educ Sci & Technol Sao Paulo, Campus Capivari, BR-13360000 Capivari, SP - Brazil
[2] Ctr Univ FAI, Itapiranga, SC - Brazil
[3] Univ Fed Itajuba, Nat Resources Inst, Bioproc Engn Course, Itajuba, MG - Brazil
[4] Sao Paulo State Univ, Fac Pharmaceut Sci, Dept Bioproc & Biotechnol, Araraquara, SP - Brazil
[5] Univ Fed Sao Carlos, Grad Program Chem Engn, CP 676, BR-13565905 Sao Carlos, SP - Brazil
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: Bioprocess and Biosystems Engineering; v. 42, n. 6, p. 995-1008, JUN 2019.
Citações Web of Science: 0
Resumo

The shear rate is an important bioreactor parameter that needs to be evaluated due to its impact on microorganism morphology and viability, and consequently on bioproduct formation. Airlift bioreactors, classified as low-shear devices, are used as an alternative to conventional stirred-tank reactors. Considerable efforts have been made to characterize the shear environments in airlift bioreactors, using the average shear rate as a key parameter. However, there is no agreement among the values obtained in different studies, which can differ even in orders of magnitude. The methodologies used to obtain av in the different studies could be the reason for the lack of agreement among them. In this work, av in a concentric tube airlift bioreactor was evaluated using computational fluid dynamics (CFD), as well as based on universal velocity profiles for liquid flows in smooth pipes and annuli. Good agreement was obtained between the CFD-based average shear rates and the values obtained from universal velocity profiles, indicating that CFD simulation is a valuable tool for av prediction. (AU)

Processo FAPESP: 11/23807-1 - Desenvolvimento e avaliação das condições de operação de biorreatores visando a produção de produtos biotecnológicos
Beneficiário:Alberto Colli Badino Junior
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 12/17756-8 - Avaliação das condições hidrodinâmicas, de cisalhamento e de transferência de oxigênio de diferentes modelos de biorreatores pneumáticos
Beneficiário:Caroline Eliza Mendes
Modalidade de apoio: Bolsas no Brasil - Doutorado