Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Incorporation of EGCG into an etch-and-rinse adhesive system: mechanical properties and bond strength to caries affected dentin

Texto completo
Autor(es):
Czech, R. [1] ; Oliveira, C. A. R. [2] ; Franca, F. M. G. [1] ; Basting, R. T. [1] ; Turssi, C. P. [1] ; Amaral, F. L. B. [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Inst Pesquisas Sao Leopoldo Mandic, Fac Sao Leopoldo Mandic, Restorat Dent, Jose Rocha Junqueira 13, Campinas, SP - Brazil
[2] Inst Fed Goiano, Campus Urutai, Urutai - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY; v. 33, n. 22 JULY 2019.
Citações Web of Science: 0
Resumo

This study evaluated how a matrix metalloproteinase (MMP) inhibitor (EGCG) incorporated into an etch-and-rinse adhesive system (AS) affects the long-term microtensile bond strength (MTBS) to caries affected dentin (CAD) and flexural strength (FS) of AS. Forty CAD surfaces received acid conditioning and were randomly divided into four groups (n = 10): EGCG-PRE - dentin treatment with 200 mu g/mL EGCG solution; EGCG-INC - 200 mu g/mL EGCG solution incorporated into SA; CHX-PRE - dentin treatment with 2% digluconate solution; NT - no treatment. The AS (Adper Single Bond 2, 3M ESPE) was applied and resin composite blocks were built on the dentin. Beam-shaped specimens (0.8 mm(2)) were obtained submitted to MTBS testing following 24 h, 6 months or 1 year of water storage (WS). Adhesive interface was analyzed by SEM. FS testing was performed by preparing specimens with the adhesive system, with or without the EGCG solution (200 mu g/mL) (n = 10). Tests were carried out in a universal machine (0.5 mm/min). MTBS data were submitted to two-way ANOVA and Tukey's test, whereas FS data, to the Student's t-test (alpha = 0.05). MTBS values were not affected by EGCG application, either incorporated or used as a dentin treatment agent, regardless of the WS period; however, CHX negatively affected MTBS to CAD (p < 0.001). WS significantly reduced MTBS values (p < 0.001) from the 6-months time point. FS was not affected by EGCG incorporation into the SA (p = 0.2527). EGCG incorporation into AS was unable to maintain bond stability to CAD over time, whereas it did not compromise adhesive's property. (AU)

Processo FAPESP: 15/06259-1 - Influência da incorporação de epigalocatequina galato em sistema adesivo convencional na resistência flexural e durabilidade de união à dentina afetada por cárie
Beneficiário:Renata Czech
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica