Development of a reliable and selective voltammetric method for determination of designer drug 1-(3-chlorophenyl)piperazine (mCPP) using boron-doped diamond electrode and exploiting surfactant-mediated measurements

Texto completo
Autor(es):
Rocha, Luana Rianne [1] ; Mendonca, Jhessica de Cassica [1] ; Capelari, Tainara Boareto [1] ; Medeiros, Roberta Antigo [1] ; Teixeira Tarley, Cesar Ricardo [1, 2]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Estadual Londrina, Dept Quim, Rod Celso Garcia Cid, PR 445 Km 380, Campus Univ, BR-86051990 Londrina, PR - Brazil
[2] Univ Estadual Campinas UNICAMP, Dept Quim Analit, Inst Nacl Ciencia & Tecnol INCT Bioanalit, Inst Quim, Cidade Univ Zeferino Vaz S-N, BR-13083970 Campinas, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: SENSORS AND ACTUATORS B-CHEMICAL; v. 310, MAY 1 2020.
Citações Web of Science: 0
Resumo

1-(3-chlorophenyl) piperazine (mCPP) is a drug abuse and its considered as one of the most well-known piperazine derivatives, exhibiting ecstasy-like stimulants and hallucinogenic effects, thereby its determination in drugs seized is of paramount importance. Electroanalysis offers a good alternative for in situ testing on seized samples, but the development of new electroanalytical methods for piperazine derivatives is still incipient. In this work, an electroanalytical method for mCPP detection and quantification using a catodically pre-treated boron-doped diamond electrode (CPT-BDDE) has been reported for the first time. Cyclic voltammograms obtained for mCPP in 0.5 mol L H2SO4 evidenced an electrochemical irreversible behavior with an anodic peak at 1.1 V. Under the optimum condition using differential pulse voltammetry, 0.5 mol L-1 Britton-Robinson buffer and pH 10, the proposed method provided an analytical curve linear over a mCPP concentration range of 3.5-400.0 mu mol L-1, with a limit of detection of 1.1 mu mol L-1. Adulterants commonly found in seized drugs, including lidocaine (LID), acetominophen (PAR), acetylsalicylic acid (AAS), caffeine (CAF), benzocaine (BEN), procaine (PRO), phenacetine (PHE), cocaine (COC) and 3,4-methylenedioxymethamphetamine (MDMA) were evaluated as possible interfering compounds. It was observed that anodic peak of mCPP was overlapped only by the presence of BEN and PRO, whose interference was overcome by using 550.0 mu mol L-1 SDS (sodium dodecyl sulfate). The developed method was applied in synthetic sample and the accuracy was attested by comparison with HPLC-DAD as the reference method. (AU)

Processo FAPESP: 14/50867-3 - INCT 2014: Instituto Nacional de Ciência e Tecnologia de Bioanalítica
Beneficiário:Marco Aurelio Zezzi Arruda
Modalidade de apoio: Auxílio à Pesquisa - Temático