Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Design and performance of novel molecularly imprinted biomimetic adsorbent for preconcentration of prostate cancer biomarker coupled to electrochemical determination by using multi-walled carbon nanotubes/Nafion (R)/Ni(OH)(2)-modified screen-printed electrode

Texto completo
Autor(es):
Mendonca, Jhessica de Cassia [1] ; da Rocha, Luana Rianne [1] ; Capelari, Tainara Boareto [1] ; Prete, Maiyara Carolyne [1] ; Angelis, Pedro Nunes [1] ; Segatelli, Mariana Gava [1] ; Teixeira Tarley, Cesar Ricardo [2, 1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Estadual Londrina UEL, Dept Quim, Ctr Ciencias Exatas, Rodovia Celso Garcia Cid, PR 445 Km 380, BR-86050482 Londrina, PR - Brazil
[2] Univ Estadual Campinas UNICAMP, Inst Nacl Ciencia & Tecnol INCT Bioanalit, Inst Quim, Dept Quim Analit, Cidade Univ Zeferino Vaz S-N, BR-13083970 Campinas, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF ELECTROANALYTICAL CHEMISTRY; v. 878, DEC 1 2020.
Citações Web of Science: 0
Resumo

The present paper describes the development of a new electroanalytical method for prostate cancer biomarker (sarcosine) by coupling molecularly imprinted solid-phase extraction (MISPE) with electrochemical determination at a MWCNT/Nafion (R)/Ni(OH)(2)-modified screen-printed electrode using a flow injection analysis (FIA) system. The synthesized MIP prepared by using dual functional monomers 2-acrylamido-2-methyl-1-propanesulfonic acid and 4vinylpyridine was characterized by Fourier Transform Infrared (FT-IR) spectroscopy, Scanning Electron Microscopy (SEM) and nitrogen adsorption/desorption measurements. The optimized pH for adsorption of sarcosine was 5.0 and the elution was completed with MeOH:HAc (90:10, v/v), whilst the electrochemical determination was performed in FIA system using a sample volume of 121.0 mu L, 0.05 mol L-1 NaOH carrier solution, a flow rate of 2.0 mL min-1 and applied potential of 0.7 V vs Ag/AgCl. The proposed method provided enrichment factor of 50.6-fold, linear analytical curve from 3.2 to 25.0 mu mol L-1 (R-2 = 0.995), and limit of detection of 0.96 mu mol L-1. The precision was evaluated in terms of intra (n = 6) and interday (n = 2) for concentrations of 10.0, 15.0, and 20.0 mu mol L-1, giving rise to low percentages of relative standard deviations (RSD %), ranging from 2.2 to 4.3%. A highly improved response for sarcosine using MIP when compared to NIP (non-imprinted polymer) was obtained. The method also exhibited higher selectivity toward sarcosine compared to glycine, alanine, proline, and urea. Analysis of synthetic urine samples yielded recoveries in the range of 95.0-108.0%, thereby indicating the absence of matrix effect and the feasibility of the method for sarcosine determination. (AU)

Processo FAPESP: 14/50867-3 - INCT 2014: Instituto Nacional de Ciência e Tecnologia de Bioanalítica
Beneficiário:Marco Aurelio Zezzi Arruda
Modalidade de apoio: Auxílio à Pesquisa - Temático