Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Design and performance of novel molecularly imprinted biomimetic adsorbent for preconcentration of prostate cancer biomarker coupled to electrochemical determination by using multi-walled carbon nanotubes/Nafion (R)/Ni(OH)(2)-modified screen-printed electrode

Full text
Author(s):
Mendonca, Jhessica de Cassia [1] ; da Rocha, Luana Rianne [1] ; Capelari, Tainara Boareto [1] ; Prete, Maiyara Carolyne [1] ; Angelis, Pedro Nunes [1] ; Segatelli, Mariana Gava [1] ; Teixeira Tarley, Cesar Ricardo [2, 1]
Total Authors: 7
Affiliation:
[1] Univ Estadual Londrina UEL, Dept Quim, Ctr Ciencias Exatas, Rodovia Celso Garcia Cid, PR 445 Km 380, BR-86050482 Londrina, PR - Brazil
[2] Univ Estadual Campinas UNICAMP, Inst Nacl Ciencia & Tecnol INCT Bioanalit, Inst Quim, Dept Quim Analit, Cidade Univ Zeferino Vaz S-N, BR-13083970 Campinas, SP - Brazil
Total Affiliations: 2
Document type: Journal article
Source: JOURNAL OF ELECTROANALYTICAL CHEMISTRY; v. 878, DEC 1 2020.
Web of Science Citations: 0
Abstract

The present paper describes the development of a new electroanalytical method for prostate cancer biomarker (sarcosine) by coupling molecularly imprinted solid-phase extraction (MISPE) with electrochemical determination at a MWCNT/Nafion (R)/Ni(OH)(2)-modified screen-printed electrode using a flow injection analysis (FIA) system. The synthesized MIP prepared by using dual functional monomers 2-acrylamido-2-methyl-1-propanesulfonic acid and 4vinylpyridine was characterized by Fourier Transform Infrared (FT-IR) spectroscopy, Scanning Electron Microscopy (SEM) and nitrogen adsorption/desorption measurements. The optimized pH for adsorption of sarcosine was 5.0 and the elution was completed with MeOH:HAc (90:10, v/v), whilst the electrochemical determination was performed in FIA system using a sample volume of 121.0 mu L, 0.05 mol L-1 NaOH carrier solution, a flow rate of 2.0 mL min-1 and applied potential of 0.7 V vs Ag/AgCl. The proposed method provided enrichment factor of 50.6-fold, linear analytical curve from 3.2 to 25.0 mu mol L-1 (R-2 = 0.995), and limit of detection of 0.96 mu mol L-1. The precision was evaluated in terms of intra (n = 6) and interday (n = 2) for concentrations of 10.0, 15.0, and 20.0 mu mol L-1, giving rise to low percentages of relative standard deviations (RSD %), ranging from 2.2 to 4.3%. A highly improved response for sarcosine using MIP when compared to NIP (non-imprinted polymer) was obtained. The method also exhibited higher selectivity toward sarcosine compared to glycine, alanine, proline, and urea. Analysis of synthetic urine samples yielded recoveries in the range of 95.0-108.0%, thereby indicating the absence of matrix effect and the feasibility of the method for sarcosine determination. (AU)

FAPESP's process: 14/50867-3 - INCT 2014: National Institute of Science and Technology in Bioanalysis
Grantee:Marco Aurelio Zezzi Arruda
Support Opportunities: Research Projects - Thematic Grants