Combined AOP/GAC/AOP systems for secondary effluent polishing: Optimization, toxicity and disinfection

Texto completo
Autor(es):
da Silva, Debora Antonio [1] ; Cavalcante, Rodrigo Pereira [2] ; Barbosa, Eric Batista [2] ; Machulek Junior, Amilcar [1] ; de Oliveira, Silvio Cesar [1] ; Dantas, Renato Falcao [2]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Fed Mato Grosso do Sul, Inst Chem, Av Senador Filinto Muller 1555, CP 549, BR-79074460 Campo Grande, MS - Brazil
[2] Univ Estadual Campinas, Sch Technol, UNICAMP, Paschoal Marino 1888, BR-13484332 Limeira, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Separation and Purification Technology; v. 263, MAY 15 2021.
Citações Web of Science: 0
Assunto(s):Ozonização
Resumo

This study reports the use of advanced oxidation processes (AOPs), specifically O-3, O-3/H2O2 and UV/H2O2, in combination with granular activated carbon (GAC) to polish secondary effluents. For this purpose, three configurations were tested: O-3-GAC-O-3, O-3/H2O2-GAC-O-3/H2O2 and UV/H2O2-GAC-UV/H2O2. The efficiency evaluation was based on the ability of the systems to remove ammaticity (UV254), organic matter (chemical oxygen demand - COD), Escherichia coli and total coliforms content as well as toxicity (Artemia salina and Allium cepa). The methods were optimized using central composite design to investigate the influence of O-3 and H2O2 concentration in the efficiency of the system and the optimal conditions were subsequently applied to treat urban secondary effluents. High organic matter removal rates were obtained by all the tested configurations, of which O-3-GAC-O-3 proved to be the most efficient. The systems were also efficient to disinfect the samples, promoting nearby 5-log reduction of E. coli and total coliforms. Acute toxicity, cytotoxicity, and genotoxicity were observed in samples subjected to the UV/H2O2-GAC-UV/H2O2 method. When used alone, GAC removed around 80% of organic matter, nevertheless failed to disinfect the samples, which furthermore exhibited acute toxicity and genotoxicity toward A. cepa. Samples subjected to direct photolysis proved more toxic than untreated samples while uncombined H2O2, O-3, GAC, and UV, as well as O-3/H2O2 and UV/H2O2 failed to degrade organic matter or to mitigate the toxicity of the samples. (AU)

Processo FAPESP: 14/17774-1 - Influência da composição do efluente secundário na desinfecção por processos oxidativos avançados
Beneficiário:Renato Falcão Dantas
Modalidade de apoio: Auxílio à Pesquisa - Jovens Pesquisadores
Processo FAPESP: 19/26210-8 - Investigação da contribuição dos processos oxidativos avançados no tratamento multibarreira de efluentes biotratados
Beneficiário:Rodrigo Pereira Cavalcante
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado