Is one dental mini-implant biomechanically appropriate for the retention of a mandibular overdenture? A comparison with Morse taper and external hexagon platforms

Texto completo
Autor(es):
Borges, Guilherme Almeida [1] ; Camacho Presotto, Anna Gabriella [1] ; Caldas, Ricardo Armini [2] ; Pisani, Marina Xavier [1] ; Mesquita, Marcelo Ferraz [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, UNICAMP, Piracicaba - Brazil
[2] Fed Univ Santa Catarina UFSC, Dept Dent, Rua Delfino Conti 1240, BR-88040900 Florianopolis, SC - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF PROSTHETIC DENTISTRY; v. 125, n. 3, p. 491-499, MAR 2021.
Citações Web of Science: 0
Resumo

Statement of problem. Limited information is available to clinicians on the use of dental mini implants (MI) as opposed to standard-diameter implants (SDIs) for the stabilization of implant retained mandibular overdentures (MOs). Purpose. The purpose of this in vitro and finite element analysis study was to analyze and compare the biomechanical behavior of MOs with either 1 or 2 implants with external hexagon (EH), Morse taper (MT) SDIs, and MIs. Material and methods. Thirty photoelastic models (n=30) of each group (n=5) of SDIs (EH-1, EH-2, MT-1, MT-2) and MI (MI-1, MI-2) were fabricated for posterior, peri-implant, and total maximum shear stress evaluation by quantitative photoelastic analysis. One specimen of each group was further used to create the 6 computational models to be analyzed by finite element analysis. The maximum von Mises values and stress maps were plotted for each ductile component. Two types of load were applied to the overdenture: a150-N load bilaterally and simultaneously on the first molar and a 100-N load on the incisal edge of the central incisors at a 30-degree angle. The data were subjected to the 2-way ANOVA test and the Tukey honestly significant difference test (a=.05). Results. The EH-2 and MT-2 showed the lowest posterior (P<.001) and total (P .05) mean shear stress values. For peri-implant shear stress, no difference was found among all groups (P .05). Regardless of the loading area, the MI-1 and MI-2 groups showed the lowest von Mises stress values. However, for implant housing, the MI-1 group, under incisor loading, presented greater stress, followed by MT-1, EH-1, EH-2, MI-2, and MT-2. The attachment was the most overloaded structure, with high values under incisor loading, especially for the groups with 2 implants (MT-2, EH-2) as compared with the other models. Conclusions. Biomechanically, regardless of the implant number, MI is a promising rehabilitation method with similar peri-implant shear stress and lower von Mises stress on the implant when compared with SDIs for MOs. (J Prosthet Dent 2021;125:491-9) (AU)

Processo FAPESP: 18/03136-4 - Overdentures mandibulares retidas por um ou dois implantes: comparação entre mini implantes e implantes convencionais com diferentes conexões - análise fotoelástica e por elementos finitos em 3D
Beneficiário:Guilherme Almeida Borges
Modalidade de apoio: Bolsas no Brasil - Mestrado
Processo FAPESP: 14/19098-3 - Influência do número e tipo de implante, conexão implante/abutment e sistemas de encaixe sobre a distribuição de tensões em Overdentures mandibulares - Análise Fotoelástica e por Elementos Finitos em 3D
Beneficiário:Marina Xavier Pisani
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado