Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Effect of occlusal anatomy of CAD/CAM feldspathic posterior crowns in the stress concentration and fracture load

Texto completo
Autor(es):
Souto Borges, Alexandre Luiz [1] ; Mendes Tribst, Joao Paulo [1] ; de Lima, Aline Lins [1] ; de Oliveira Dal Piva, Amanda Maria [1] ; Ozcan, Mutlu [2]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ UNESP, Inst Sci & Technol, Dept Dent Mat & Prosthet, Sao Jose Dos Campos - Brazil
[2] Univ Zurich, Ctr Dent & Oral Med, Div Dent Biomat, Clin Reconstruct Dent, Plattenstr 11, CH-8032 Zurich - Switzerland
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: CLINICAL AND EXPERIMENTAL DENTAL RESEARCH; JUL 2021.
Citações Web of Science: 0
Resumo

Objectives: This study evaluated the effect of restoration occlusal design on the maximum fracture load and stress distribution of a feldspathic ceramic crown. Materials and Methods: Twenty dentin analogues were used to simulate a full-crown preparation. Next, 20 feldspathic crowns were milled according to the occlusal design parameter available in the CAD database (Young or Adult). The crowns were cemented with dual cure resin-cement and loaded until fracture at 1 mm/min cross-head speed. Data were analyzed by using one-way ANOVA and Tukey tests (p < 0.05). The same geometry and experimental setup was modeled and exported to the computer aided engineering software and tensile stress concentration was calculated using the finite element method with 300 N occlusal load simulation. Results: The occlusal anatomy significantly influenced the load-to-fracture (p < 0.05). Adult design showed higher mean values (1149 +/- 201 N) than Young design (454 +/- 77 N). The maximum principal stress criteria showed similar stress pattern for both designs, however, the highest stress concentration was calculated for Young design (91 MPa) in the occlusal surface. Conclusions: An anatomy design with reduced cusp angulation and less evident occlusal sulcus can reduce the stress concentration and increase the fracture load for feldspathic CAD/CAM posterior crowns. (AU)

Processo FAPESP: 13/14831-1 - Influência da inclinação das cúspides e rigidez de material restaurador na distribuição de cargas e resistência à fratura de restaurações totais
Beneficiário:Aline Lins de Lima
Modalidade de apoio: Bolsas no Brasil - Mestrado
Processo FAPESP: 14/00668-4 - Influência da anatomia oclusal, propriedade de cimentos resinosos e tipo de conectores na resistência mecânica e distribuição de tensão em próteses fixas metal free
Beneficiário:Alexandre Luiz Souto Borges
Modalidade de apoio: Auxílio à Pesquisa - Regular