Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Effect of different tightening protocols on the probability of survival of screw-retained implant-supported crowns

Texto completo
Autor(es):
Fardin, Vinicius P. [1] ; Bergamo, Edmara T. P. [1] ; Bordin, Dimorvan [2] ; Hirata, Ronaldo [3] ; Bonfante, Estevam A. [1] ; Bonfante, Gerson [1] ; Coelho, Paulo G. [4, 5, 3]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Bauru Coll Dent, Dept Prosthodont & Periodontol, Bauru, SP - Brazil
[2] Univ Universus Veritas UNG, Dept Restorat Dent, Guarulhos, SP - Brazil
[3] NYU, Dept Biomat & Biomimet, Coll Dent, New York, NY 10003 - USA
[4] NYU, Tandon Sch Engn, Mech & Aerosp Engn, New York, NY - USA
[5] NYU, Hansjorg Wyss Dept Plast Surg, Langone Med Ctr, New York, NY - USA
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS; v. 126, FEB 2022.
Citações Web of Science: 0
Resumo

Purpose: This study evaluated the effect of different tightening protocols on the probability of survival of screw-retained implant-supported anterior crowns. Materials and methods: Seventy-two implants with internal conical connections (4.0 x 10mm, Ti-6Al-4V, Colosso, Emfils) were divided into four groups (n = 18 each): 1) Manufacturer's recommendations torque (25 N. cm for abutment's screw and 30 N.cm for crown's screw) (MaT); 2) Retightening after 10 min (ReT); 3) Torque 16% below recommended to simulate an uncalibrated wrench (AgT), and; 4) Temporary crown simulation (TeT), where crowns were torqued to 13 N.cm to simulate manual tightening, subjected to 11,200 cycles to simulate temporary crown treatment time (190 N), and then retightened to manufacturer torque (TeT). All specimens were subjected to cyclic fatigue in distilled water with a load of 190 N until 250,000 cycles or failure. The probability of survival (reliability) to complete a mission of 50,000 cycles was calculated and plotted using the Weibull 2-Parameter analysis. Weibull modulus and number of cycles at which 62.3% of the specimens would fail were also calculated and plotted. The failure mode was characterized in stereo and scanning electron microscopes (SEM). Results: The probability of survival was 69.3% for MaT, 70% for ReT, 54.8% for AgT, and 40.3% for TeT, all with no statistically significant difference. Weibull modulus was approximately 1.0 for all groups. The characteristic number of cycles for failure was 105,000 cycles for MaT, 123,000 for ReT, 82,000 cycles for AgT, and 54,900 cycles for TeT, with no significant difference between groups. The chief failure mode for MaT, ReT, AgT groups was crown screw fracture, whereas abutment screw fracture was the chief failure mode for the TeT group. Conclusion: Tightening protocol did not influence the probability of survival of the screw-retained anterior crowns supported by internal conical implants (Ti-6Al-4V, Colosso, Emfils). (AU)

Processo FAPESP: 21/08018-2 - Caracterização nanomecânica de compósitos ZTA e ATZ infiltrados por vidro
Beneficiário:Edmara Tatiely Pedroso Bergamo
Modalidade de apoio: Bolsas no Exterior - Estágio de Pesquisa - Pós-Doutorado
Processo FAPESP: 11/16377-0 - Avaliação da confiabilidade e modo de falha de coroas de sistemas cerâmicos em função do desenho da infra-estrutura e do local de aplicação da carga
Beneficiário:Vinicius Pavesi Fardin
Modalidade de apoio: Bolsas no Brasil - Mestrado
Processo FAPESP: 16/18818-8 - EMU concedido no processo 2012/19078-7: ElectroPuls E3000 Linear-Torsion All-Electric dynamic test instrument package
Beneficiário:Estevam Augusto Bonfante
Modalidade de apoio: Auxílio à Pesquisa - Programa Equipamentos Multiusuários
Processo FAPESP: 13/20806-0 - Avaliação dos danos e modo de falha de próteses parciais fixas totalmente cerâmicas em função da aplicação de carga na crista marginal
Beneficiário:Vinicius Pavesi Fardin
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 14/22859-6 - Efeito do desenho de infraestruturas de próteses parciais fixas de zircônia fadigadas quanto as propriedades nanomecânicas
Beneficiário:Vinicius Pavesi Fardin
Modalidade de apoio: Bolsas no Exterior - Estágio de Pesquisa - Doutorado
Processo FAPESP: 21/06730-7 - Rumo à zircônia sustentável reciclada a partir do descarte de usinagem e melhorada por infiltração graduada e ao desenvolvimento de blocos de zircônia multicamada resistentes, graduados, e não suscetíveis ao envelhecimento
Beneficiário:Estevam Augusto Bonfante
Modalidade de apoio: Auxílio à Pesquisa - Jovens Pesquisadores - Fase 2
Processo FAPESP: 11/23177-8 - Avaliação da confiabilidade e modo de falha de coroas de sistemas cerâmicos em função do desenho da infra-estrutura e do local de aplicação da carga
Beneficiário:Gerson Bonfante
Modalidade de apoio: Auxílio à Pesquisa - Regular