Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

valuation of Pulsating Pressure and Emitter Position in Preventing Drip Emitters from Cloggin

Texto completo
Autor(es):
Fernandes, Caio Nascimento [1] ; Saad, Joao Carlos Cury [1]
Número total de Autores: 2
Afiliação do(s) autor(es):
[1] UNESP Univ Estadual Paulista, Fac Ciencias Agron Botucatu, Rua Jose Barbosa Barros 1780, Caixa Postal 237, BR-18603970 Botucatu, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING; v. 148, n. 3 MAR 1 2022.
Citações Web of Science: 0
Resumo

Non-pressure compensating (Non-PC) emitters are employed mainly in drip irrigation systems due to their structural simplicity and low manufacturing costs; however, they present high sensitivity to physical obstruction, even when using filtration. This research aimed to analyze the effects of pulsating pressure, constant pressure, and water exit position in terms of preventing clogging in Non-PC drippers with a labyrinth system. The tests were performed on a test bench, and each treatment had 68 drippers (repetitions). Quartz sand was added to the irrigation water at a 500 mg L-1 concentration in two granulometric ranges (53-105 and 250-500 mu m) to reproduce field conditions. The performance indicators were emitter flow rate (L h(-1)) and relative flow rate (q(r)). For the 250-500 mu m granulometric range and the emitters positioned with the water exit facing downward, the 30 s constant pressure and 1 min pulsating pressure resulted in the obstruction of all emitters with only 2 h of operation. In the 53-105 mu m granulometric range with the emitter hole facing downward, a pulsating pressure with a 1 min cycle was the most efficient at delaying emitter clogging, showing q(r) > 75% during the first 16 h of operation. When the dripper exit was positioned facing upward in the most critical situation (constant pressure), no clogging was observed within the two granulometric ranges during the 40 h test. For this emitter model, which is widely applied in horticulture, a water exit facing upward is recommended to prevent clogging by suspended solid particles. (C) 2021 American Society of Civil Engineers. (AU)

Processo FAPESP: 18/12006-7 - Utilização de pressão pulsante na prevenção de entupimento de gotejadores não regulados
Beneficiário:Caio Nascimento Fernandes
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica