Exploring CBCT-Based DICOM Files. A Systematic Review on the Properties of Images Used to Evaluate Maxillofacial Bone Grafts

Texto completo
Autor(es):
Spin-Neto, Rubens [1, 2] ; Marcantonio, Jr., Elcio [2] ; Gotfredsen, Erik [1] ; Wenzel, Ann [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Aarhus Univ, Dept Oral Radiol, Sch Dent, DK-8000 Aarhus C - Denmark
[2] UNESP Univ Estadual Paulista, Dept Periodontol, Araraquara Dent Sch, Sao Paulo - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF DIGITAL IMAGING; v. 24, n. 6, p. 959-966, DEC 2011.
Citações Web of Science: 25
Resumo

Previous studies suggests that cone beam computerized tomography (CBCT) images could provide reliable information regarding the fate of bone grafts in the maxillofacial region, but no systematic information regarding the standardization of CBCT settings and properties is available, i.e., there is a lack of information on how the images were generated, exported, and analyzed when bone grafts were evaluated. The aim of this study was to (1) do a systematic review on which type of CBCT-based DICOM images have been used for the evaluation of the fate of bone grafts in humans and (2) use a software suggested in the literature to test DICOM-based data sets, exemplifying the effect of variation in selected parameters (windowing/contrast control, plane definition, slice thickness, and number of measured slices) on the final image characteristics. The results from review identified three publications that used CBCT to evaluate maxillofacial bone grafts in humans, and in which the methodology/results comprised at least one of the expected outcomes (image acquisition protocol, image reconstruction, and image generation information). The experimental shows how the influence of information that was missing in the retrieved papers, can influence the reproducibility and the validity of image measurements. Although the use of CBCT-based images for the evaluation of bone grafts in humans has become more common, this does not reflect on a better standardization of the developed studies. Parameters regarding image acquisition and reconstruction, while important, are not addressed in the proper way in the literature, compromising the reproducibility and scientific impact of the studies. (AU)

Processo FAPESP: 08/09207-9 - Enxertos ósseos homólogos em humanos: avaliação imunológica, tomográfica, histológica e histométrica de sua incorporação e capacidade de osseointegrar implantes
Beneficiário:Elcio Marcantonio Junior
Modalidade de apoio: Auxílio à Pesquisa - Regular