Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis

Texto completo
Autor(es):
Grazielle Franco Gomes [1] ; Mónica Estefanía Tinajero Aroni [2] ; Lucas Portela Oliveira [3] ; João Neudenir Arioli Filho [4] ; Carolina Mollo Binda [5] ; Francisco de Assis Mollo Júnior [6]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] São Paulo State University. School of Dentistry. Department of Dental Materials and Prosthodontics - Brasil
[2] São Paulo State University. School of Dentistry. Department of Dental Materials and Prosthodontics - Brasil
[3] São Paulo State University. School of Dentistry. Department of Dental Materials and Prosthodontics - Brasil
[4] São Paulo State University. School of Dentistry. Department of Dental Materials and Prosthodontics - Brasil
[5] University Center of Araraquara. Dental School. Department of Health Sciences - Brasil
[6] São Paulo State University. School of Dentistry. Department of Dental Materials and Prosthodontics - Brasil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: Braz. J. Oral Sci.; v. 22, 2023-08-14.
Resumo

Aim To analyze the accuracy of extraoral systems (Ceramill Map400+, AutoScan-DS200+, and E2) in full implant-prosthetic rehabilitation three-dimensionally. Methods A metallic edentulous maxilla with four implants was digitalized by a contact scanner (MDX-40 - Roland, control) and used as a control image to compare with other images generated by three laboratory scanners (10 samples per group). Letters identified all the four components: A and D angled 45º, and B and C parallel. The BioCAD software exported the images (.STL) to compare and verify deviations of the analogs on the X, Y, and Z axes. The nonparametric Kruskal-Wallis test and the two-way ANOVA on ranks with a post hoc Tukey test analyzed the data with 5% significance. Results No statistical differences were observed in the accuracy between the extraoral scanners (p=0.0806). However, when analyzing only the components, component D was more accurate when scanned with Ceramill Map400+ compared with AutoScan DS200+ (p<0.001) and with E2 (p=0.002). Conclusions All extraoral systems assessed showed digitalization accuracy but with more deviations in angled implants. The Ceramill Map400+ scanner showed the best results for the digital impression of a complete arch. (AU)

Processo FAPESP: 19/22509-9 - Análise tridimensional em moldagem digital: há precisão em sistemas laboratoriais?