Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Influence of Microwave Disinfection on the Dimensional Stability of Denture Reline Polymers

Texto completo
Autor(es):
Manzolli Basso, Michael Frederico [1] ; Giampaolo, Eunice Teresinha [1] ; Vergani, Carlos Eduardo [1] ; Machado, Ana Lucia [1] ; Pavarina, Ana Claudia [1] ; Ribeiro, Roberta Chuqui [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ, Dept Dent Mat & Prosthodont, Araraquara Dent Sch, UNESP, BR-14801903 Araraquara, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY; v. 19, n. 5, p. 364-368, JUL 2010.
Citações Web of Science: 7
Resumo

Purpose: The purpose of this study was to evaluate the effect of microwave disinfection (3 minutes at 650 W) on the dimensional stability of hard chairside reline resins (Kooliner, Tokuyama Rebase II, Ufi Gel hard, New Truliner) and one heat-polymerizing denture base resin (Lucitone 550). Materials and Methods: A split mold with reference points was used to make specimens (50.0-mm diameter, 0.5-mm thick) from each material, divided into five test groups (n = 8). The distances between the points on the mold were measured (gold standard), and compared with those obtained from the specimens after polymerization (baseline readings) after one, two, three, and four cycles of disinfection by microwave irradiation. Results: ANOVA and Tukey tests (alpha = 0.05) showed that Kooliner was significantly affected by all disinfection cycles (p < 0.05) when compared with baseline measurements. New Truliner resin was significantly affected by three and four cycles of microwave disinfection when compared with baseline measurements (p < 0.05). For Tokuyama Rebase II, Ufi Gel hard, and Lucitone 550, no significant dimensional changes were found. Conclusions: Microwave disinfection promoted shrinkage of Kooliner and New Truliner. The dimensional stability of Tokuyama Rebase II, Ufi Gel Hard, and Lucitone 550 was not affected by microwave disinfection. (AU)

Processo FAPESP: 05/04693-4 - 1. Avaliação clínica da alteração dimensional de próteses totais submetidas à desinfecção por microondas; 2. Efeito do tempo e do método de desinfecção no desempenho clínico e na quantificação de microrganismos de um reembasador rígido
Beneficiário:Eunice Teresinha Giampaolo
Modalidade de apoio: Auxílio à Pesquisa - Regular