Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Correlation between light transmission and permeability of human dentin

Texto completo
Autor(es):
Silveira Turrioni, Ana Paula [1] ; de Oliveira, Camila Favero [1] ; Basso, Fernanda Goncalves [2] ; Moriyama, Lilian Tan [3] ; Kurachi, Cristina [3] ; Hebling, Josimeri [1] ; Bagnato, Vanderlei S. [3] ; de Souza Costa, Carlos Alberto [4, 5]
Número total de Autores: 8
Afiliação do(s) autor(es):
[1] Univ Estadual Paulista, Dept Pediat Dent & Orthodont, BR-14801903 Araraquara, SP - Brazil
[2] Univ Estadual Paulista, Dept Oral Diag, BR-14801903 Araraquara, SP - Brazil
[3] USP Univ Sao Paulo, Inst Phys, BR-13560970 Sao Carlos, SP - Brazil
[4] Univ Estadual Paulista, Dept Fisiol & Patol, Fac Odontol Araraquara, BR-14801903 Araraquara, SP - Brazil
[5] UNESP Univ Estadual Paulista, Dept Physiol & Pathol, BR-14801903 Araraquara, SP - Brazil
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: Lasers in Medical Science; v. 27, n. 1, p. 191-196, JAN 2012.
Citações Web of Science: 12
Resumo

The influence of dentin permeability on transdentinal LED light propagation should be evaluated since this kind of phototherapy may further be clinically used to stimulate the metabolism of pulp cells, improving the healing of damaged pulps. This study evaluated the influence of the dentin permeability on the transdentinal LED light (630 nm) transmission. Forty-five 0.5-mm-thick dentin disks were prepared from the coronal dentin of extracted sound human molars. An initial measurement of transdentinal LED light transmission was carried out by illuminating the discs in the occlusal-to-pulpal direction onto a light power sensor to determine light attenuation. The discs were treated with EDTA for smear layer removal, subjected to analysis of hydraulic conductance, and a new measurement of transdentinal LED light transmission was taken. Spearman's correlation coefficient was used for analysis of data and showed a weak correlation between dentin permeability and light attenuation (coefficient = 0.19). This result indicates that higher or lower dentin permeability does not reflect the transdentinal propagation of LED light. Significantly greater transdentinal propagation of light was observed after treatment of dentin surface with EDTA (Wilcoxon test, p < 0.05). According to the experimental conditions of this in vitro study, it may be concluded that dentin permeability does not interfere in the transdentinal LED light transmission, and that smear layer removal facilitates this propagation. (AU)

Processo FAPESP: 09/03615-0 - Efeito transdentinário de diferentes tipos de LEDs sobre cultura de células odontoblásticas.
Beneficiário:Ana Paula Silveira Turrioni
Modalidade de apoio: Bolsas no Brasil - Mestrado
Processo FAPESP: 10/50798-0 - Efeito trandentinario de diferentes tipos de LED sobre cultura de células odontoblásticas
Beneficiário:Carlos Alberto de Souza Costa
Modalidade de apoio: Auxílio à Pesquisa - Regular