Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Feasibility study for the preparation of a tuna fish candidate reference material for total As determination

Texto completo
Autor(es):
Carioni, V. M. O. [1] ; Chelegao, R. [1] ; Naozuka, J. [2] ; Nomura, C. S. [1, 3]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Fed ABC, Ctr Ciencias Nat & Humanas, BR-09210170 Santo Andre, SP - Brazil
[2] Univ Fed Sao Paulo, Dept Ciencias Exatas & Terra, BR-09972270 Diadema, SP - Brazil
[3] Univ Sao Paulo, Inst Quim, BR-05508000 Sao Paulo - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: ACCREDITATION AND QUALITY ASSURANCE; v. 16, n. 8-9, p. 453-458, AUG 2011.
Citações Web of Science: 10
Resumo

This work describes the evaluation of several parameters for the preparation of a tuna fish candidate as a reference material (RM) in order to measure the total As mass fraction by slurry sampling graphite furnace atomic absorption spectrometry (SLS-GF AAS) and slurry sampling hydride generation atomic absorption spectrometry (SLS-HG AAS). The main parameters investigated were the homogeneity, analyte segregation and composition during material production. For candidate RM preparation, tuna fish was collected at a local market, cleaned, freeze-dried and treated using different procedures as follows: (1) ground in a cutting mill and separated in different particle sizes (2) ground in cryogenic mill. The mass fraction of As in the cryogenically ground sample was (4.77 +/- A 0.19) mu g g(-1) for SLS-GF AAS and (4.61 +/- A 0.34) mu g g(-1) for SLS-HG AAS. The accuracy of the procedures was checked with tuna fish certified reference material (BCR 627) with recoveries of 102 and 94% for SLS-GF AAS and SLS-HG AAS, respectively. The homogeneity factor was calculated for different pretreatment procedures and for particle sizes in the range of 500-150 mu g, indicating good homogeneity, except for raw fish. There was no observed analyte segregation and no losses, no contamination and no changes in the microdistribution of material during preparation. (AU)

Processo FAPESP: 07/56504-6 - Avaliação de parâmetros e produção de materiais de referência de sangue, tecido muscular e vísceras de peixe para controle ecotoxicológico
Beneficiário:Cassiana Seimi Nomura
Modalidade de apoio: Auxílio à Pesquisa - Jovens Pesquisadores