Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Quantification of major and trace elements in water samples by ICP-MS and collision cell to attenuate Ar and Cl-based polyatomic ions

Texto completo
Autor(es):
Bueno Cotta, Aloisio Jose [1] ; Enzweiler, Jacinta [1]
Número total de Autores: 2
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Inst Geosci, UNICAMP, BR-13083970 Campinas, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Journal of Analytical Atomic Spectrometry; v. 24, n. 10, p. 1406-1413, 2009.
Citações Web of Science: 31
Resumo

Inductively coupled plasma mass spectrometry (ICP-MS) is the best fitted analytical technique for multi-element analysis of waters, because of its low detection limits. One limitation is the polyatomic interferences produced in the plasma and in the interface (e.g., (35)Cl(16)O(+) on (51)V(+), (40)Ar (16)O(+) on (56)Fe(+), (40)Ar(35) Cl(+) on (75)As(+) and (40)Ar(38) Ar(+) on (78)Se(+)). These polyatomic ions can be significantly reduced by ion molecule interactions in a collision cell (CC). Several experiments done in a ICP-MS equipped with a CC pressurized by premixed H(2) 7% in He, under optimized gas flow rates, demonstrate the beneficial effect of KED to suppress Ar and Cl-based interferences. These results are opposed to reports where the role of KED was denied. Under such conditions the background equivalent concentration of (51)V, (52)Cr, (56)Fe, (63)Cu, (75)As and (78)Se were improved by two orders of magnitude, allowing the quantification of these elements at low ng L (1) level, without the need for mathematical corrections. Moreover, we present results obtained with a multi-mode method of analysis for twenty eight elements in two water certified reference materials (CRM). In this method isotopes free from polyatomic interferences are measured in standard mode and interfered ones using CC mode. The certified and reference values were used to evaluate the analytical trueness, which was better than 5%, with all z-scores within the recommended limit. Intermediate precision was mostly better than 6% and method detection limits are fit for hydrogeochemical studies and to monitor regulated toxic trace elements in waters. (AU)

Processo FAPESP: 03/09916-6 - Ambiente tectônico e metalogênese dos depósitos de ouro e cobre das províncias minerais do Tapajós (MT) e Carajás (PA)
Beneficiário:Carlos Roberto de Souza Filho
Modalidade de apoio: Auxílio à Pesquisa - Programa PRONEX - Temático