Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Commercially pure titanium implants with surfaces modified by laser beam with and without chemical deposition of apatite. Biomechanical and topographical analysis in rabbits

Texto completo
Autor(es):
Queiroz, Thallita P. [1, 2, 3] ; Souza, Francisley A. [1, 2] ; Guastaldi, Antonio C. [4] ; Margonar, Rogerio [3] ; Garcia-Junior, Idelmo R. [1, 2] ; Hochuli-Vieira, Eduardo [1, 2]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Unesp Univ Estadual Paulista, Dept Surg, Dent Sch Aracatuba, Aracatuba - Brazil
[2] Unesp Univ Estadual Paulista, Integrated Clin, Div Oral & Maxillofacial Surg, Aracatuba - Brazil
[3] Univ Ctr Araraquara UNIARA, Div Implantol, Dept Hlth Sci, Araraquara - Brazil
[4] Unesp Univ Estadual Paulista, Inst Chem, Dept Biomat, Araraquara - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: Clinical Oral Implants Research; v. 24, n. 8, p. 896-903, AUG 2013.
Citações Web of Science: 12
Resumo

Objectives The purpose of this study was to evaluate the surfaces of commercially pure titanium (cp Ti) implants modified by laser beam (LS), without and with hydroxyapatite deposition by the biomimetic method (HAB), without (HAB) and with thermal treatment (HABT), and compare them with implants with surfaces modified by acid treatment (AS) and with machined surfaces (MS), employing topographical and biomechanics analysis. Methods Forty-five rabbits received 75 implants. After 30, 60, and 90days, the implants were removed by reverse torque and the surfaces were topographically analyzed. Results At 30days, statistically significant difference (P<0.05) was observed among all the surfaces and the MS, between HAB/HABT and AS and between HAB and LS. At 60days, the reverse torque of LS, HAB, HABT, and AS differed significantly from MS. At 90days, difference was observed between HAB and MS. The microtopographic analysis revealed statistical difference between the roughness of LS, HAB, and HABT when compared with AS and MS. Conclusions It was concluded that the implants LS, HAB, and HABT presented physicochemical and topographical properties superior to those of AS and MS and favored the osseointegration process in the shorter periods. In addition, HAB showed the best results when compared with other surfaces. (AU)

Processo FAPESP: 08/01613-8 - Estudo comparativo in vivo empregando-se implantes de Ticp com diferentes superfícies: modificadas por ataque ácido, laser sem e com recobrimento de hidroxiapatita e com silicato de sódio
Beneficiário:Eduardo Hochuli Vieira
Modalidade de apoio: Auxílio à Pesquisa - Regular