Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Voltammetric Determination of Cocaine in Confiscated Samples Using a Carbon Paste Electrode Modified with Different [UO2(X-MeOsalen)(H2O)]center dot H2O Complexes

Texto completo
Autor(es):
de Oliveira, Laura Siqueira [1] ; dos Santos Poles, Ana Paula [1] ; Balbino, Marco Antonio [1] ; Teles de Menezes, Matheus Manoel [1] ; de Andrade, Jose Fernando [1] ; Dockal, Edward Ralph [2] ; Tristao, Heloisa Maria [3] ; de Oliveira, Marcelo Firmino [1]
Número total de Autores: 8
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Quim, BR-14040901 Ribeirao Preto, SP - Brazil
[2] Univ Fed Sao Carlos, Dept Quim, Ctr Ciencias Exatas & Tecnol, BR-13565905 Sao Carlos, SP - Brazil
[3] Superintendencia Policia Tecn Cient Estado Sao Pa, Nucleo Pericias Criminalist Ribeirao Preto, BR-14015040 Ribeirao Preto, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: SENSORS; v. 13, n. 6, p. 7668-7679, JUN 2013.
Citações Web of Science: 16
Resumo

A fast and non-destructive voltammetric method to detect cocaine in confiscated samples based on carbon paste electrode modified with methoxy-substituted N,N'-ethylene-bis(salcylideneiminato)uranyl(VI)complexes, {[}UO2(X-MeOSalen)(H2O)]center dot H2O, where X corresponds to the positions 3, 4 or 5 of the methoxy group on the aromatic ring, is described. The electrochemical behavior of the modified electrode and the electrochemical detection of cocaine were investigated using cyclic voltammetry. Using 0.1 mol.L-1 KCl as supporting-electrolyte, a concentration-dependent, well-defined peak current for cocaine at 0.62 V, with an amperometric sensitivity of 6.25 x 10(4) mu A.mol.L-1 for cocaine concentrations ranging between 1.0 x 10(-7) and 1.3 x 10(-6) mol.L-1 was obtained. Chemical interference studies using lidocaine and procaine were performed. The position of the methoxy group affects the results, with the 3-methoxy derivative being the most sensitive. (AU)

Processo FAPESP: 12/00084-7 - Desenvolvimento de eletrodos quimicamente modificados para a determinação voltamétrica de cocaína, MDMA, LSD e D-9-tetraidrocanabinol em amostras de interesse judicial
Beneficiário:Marcelo Firmino de Oliveira
Modalidade de apoio: Auxílio à Pesquisa - Regular