Electrochemical sensor for ranitidine determination based on carbon paste electrode modified with oxovanadium (IV) salen complex

Texto completo
Autor(es):
Raymundo-Pereira, Paulo A. [1, 2] ; Teixeira, Marcos F. S. [1] ; Fatibello-Filho, Orlando [3] ; Dockal, Edward R. [3] ; Bonifacio, Viviane Gomes [4] ; Marco Lino-Junior, Luiz H. [4]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Estadual Paulista, Fac Ciencias & Tecnol, Dept Fis Quim & Biol, Presidente Prudente, SP - Brazil
[2] Univ Sao Paulo, Inst Quim, BR-13566590 Sao Paulo - Brazil
[3] Univ Fed Sao Carlos, Cent Ciencias Exatas & Tecnol, Dept Quim, BR-13560 Sao Carlos, SP - Brazil
[4] Univ Fed Parana, Dept Quim, BR-81531990 Curitiba, PR - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: Materials Science & Engineering C-Materials for Biological Applications; v. 33, n. 7, p. 4081-4085, OCT 1 2013.
Citações Web of Science: 13
Resumo

The preparation and electrochemical characterization of a carbon paste electrode modified with the N, N-ethylene-bis(salicyllideneiminato)oxovanadium (IV) complex ({[}VO(salen)]) as well as its application for ranitidine determination are described. The electrochemical behavior of the modified electrode for the electroreduction of ranitidine was investigated using cyclic voltammetry, and analytical curves were obtained for ranitidine using linear sweep voltammetry (LSV) under optimized conditions. The best voltammetric response was obtained for an electrode composition of 20% (m/m) {[}VO(salen)] in the paste, 0.10 mol L-1 of KCl solution (pH 5.5 adjusted with HCl) as supporting electrolyte and scan rate of 25 mV s(-1), A sensitive linear voltammetric response for ranitidine was obtained in the concentration range from 9.9 x 10(-5) to 1.0 x 10(-3) mol L-1, with a detection limit of 6.6 x 10(-5) mol L-1 using linear sweep voltammetry. These results demonstrated the viability of this modified electrode as a sensor for determination, quality control and routine analysis of ranitidine in pharmaceutical formulations. (C) 2013 Published by Elsevier B.V. (AU)

Processo FAPESP: 08/07298-7 - Estudo de filmes poliméricos de complexos à base de tiofeno-Schiff na construção de sensores eletroquímicos
Beneficiário:Paulo Augusto Raymundo Pereira