Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Rapid determination of 12 antibiotics and caffeine in sewage and bioreactor effluent by online column-switching liquid chromatography/tandem mass spectrometry

Texto completo
Autor(es):
Lima Gomes, Paulo C. F. [1, 2] ; Tomita, Ins N. [2] ; Santos-Neto, Alvaro J. [3] ; Zaiat, Marcelo [2]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ UNESP, Inst Chem, Dept Analyt Chem, BR-14800060 Araraquara, SP - Brazil
[2] Univ Sao Paulo, Sao Carlos Sch Engn EESC, Ctr Res Dev & Innovat Environm Engn, Environm Engn, Biol Proc Lab, BR-13563120 Sao Carlos, SP - Brazil
[3] Univ Sao Paulo, Inst Chem Sao Carlos, BR-13560970 Sao Carlos, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: ANALYTICAL AND BIOANALYTICAL CHEMISTRY; v. 407, n. 29, p. 8787-8801, NOV 2015.
Citações Web of Science: 11
Resumo

This study presents a column-switching solid-phase extraction online-coupled to a liquid chromatography/tandem mass spectrometry (SPE-LC-MS/MS) method for simultaneous analysis of 12 antibiotics (7 sulfonamides and 5 fluoroquinolones) and caffeine detected in the sewage and effluent of a pilot anaerobic reactor used in sewage treatment. After acidification and filtration, the samples were directly injected into a simple and conventional LC system. Backflush and foreflush modes were compared based on the theoretical plates and peak asymmetry observed. The method was tested in terms of detection (MDL) and quantification limit (MQL), linearity, relative recovery, and precision intra- and inter-day in lab-made sewage samples. The method presented suitable figures of merit in terms of detection, varying from 8.00 x 10(-5) to 6.00 x 10(-2) ng (0.800 up to 600 ng L-1; caffeine) with direct injection volume of only 100 mu L and 13 min of total analysis time (sample preparation and chromatographic run). When the method was applied in the analysis of sewage and effluent of the anaerobic reactor (n = 15), six antibiotics and caffeine were detected in concentrations ranging from 0.018 to 1097 mu g L-1. To guarantee a reliable quantification, standard addition was used to overcome the matrix effect. (AU)

Processo FAPESP: 09/15984-0 - Produção de bioenergia no tratamento de águas residuárias e adequação ambiental dos efluentes e resíduos gerados
Beneficiário:Marcelo Zaiat
Modalidade de apoio: Auxílio à Pesquisa - Temático
Processo FAPESP: 10/19910-9 - Desenvolvimento de estratégias de química verde em cromatografia e aplicação na avaliação da degradação de antibióticos em águas residuárias por biorreatores anaeróbios de leito fixo
Beneficiário:Alvaro José dos Santos Neto
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 12/07153-4 - Análise e identificação de produtos de degradação de resíduos de antibióticos após tratamento em reatores anaeróbios
Beneficiário:Paulo Clairmont Feitosa de Lima Gomes
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado