Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Combination of Dispersive Liquid Liquid Microextraction and Emulsion Breaking for the Determination of Cu(II) and Pb(II) in Biodiesel and Oil Samples

Texto completo
Autor(es):
Lima, Lucas C. [1] ; Paixao, Thiago R. L. C. [2] ; Nomura, Cassiana S. [2] ; Gaubeur, Ivanise [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Fed ABC, Ctr Ciencias Nat & Humanas, Av Estados 5001, BR-09210971 Sao Paulo - Brazil
[2] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, Av Prof Lineu Prestes 748, BR-05508000 Sao Paulo - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: ENERGY & FUELS; v. 31, n. 9, p. 9491-9497, SEP 2017.
Citações Web of Science: 3
Resumo

Trace element determination in oil and biodiesel samples is not a simple task. To improve detectability and minimize the matrix effect, a preconcentration procedure before analysis is often required. In this work, we apply dispersive liquid-liquid microextraction to the determination of copper and lead in biodiesel and oil samples. The complexes formed between Cu(II), Pb(II), and di-2-pyridyl ketone salicyloylhydrazone were extracted using 1-undecanol as an extractant solvent and ethanol as a disperser solvent. The concentration of analytes was determined using graphite furnace atomic absorption spectrometry after matrix modification and Zeeman background correction. The complexant concentration, pH value, and extractant solvent volume were optimized using a multivariate consisting of a central composite design and a univariate analysis. Under optimum complexation and microextraction conditions (pH 9.2, 50 mu L of extractant, and 150,mu L of disperser solvent), calibration curves were obtained with linear ranges of 1.0-25 mu g L-1 (Cu(II)) and 1.0-40 mu g L-1 (Pb(II)) and limits of detection of 0.23 and 0.24 mu g L-1 for Cu(II) and Pb(II), respectively. Before microextraction, an emulsion-breaking procedure was applied in biodiesel and oil samples by mixing 100 mg of sample with 100 mu L of hexane, 8% (w/v) Triton X-114, and 3.3 mol L-1 HNO3. The accuracy of the proposed method was confirmed through the analysis of two standard reference materials (B100 biodiesel soy-based and Conostan oil analysis standards) and mineral oil and corn biodiesel samples. (AU)

Processo FAPESP: 11/19730-3 - Emprego da extração em ponto nuvem (CPE) e da microextração líquido-líquido dispersiva (DLLME) no desenvolvimento de métodos analíticos para a pré-concentração e determinação espectrométrica de metais
Beneficiário:Ivanise Gaubeur
Modalidade de apoio: Auxílio à Pesquisa - Regular