A fast and simple air-assisted liquid-liquid microextraction procedure for the simultaneous determination of bisphenols, parabens, benzophenones, triclosan, and triclocarban in human urine by liquid chromatography-tandem mass spectrometry

Texto completo
Autor(es):
Rocha, Bruno Alves [1] ; Moraes de Oliveira, Anderson Rodrigo [2] ; Barbosa, Jr., Fernando [1]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Fac Ciencias Farmaceut Ribeirao Preto, Lab Toxicol & Essencialidade Metais, BR-14049903 Ribeirao Preto, SP - Brazil
[2] Univ Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Quim, BR-14049901 Ribeirao Preto, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Talanta; v. 183, p. 94-101, JUN 1 2018.
Citações Web of Science: 20
Resumo

The increasing awareness and public concern with hazard exposure to endocrine-disrupting chemicals calls for methods capable to handle numerous samples in short analysis time. In this present study, a novel method combining air-assisted liquid-liquid microextraction and liquid chromatography coupled to mass spectrometry was developed and validated for the extraction, preconcentration, and determination of 7 bisphenols (bisphenol A, bisphenol S, bisphenol AP, bisphenol P, bisphenol F, bisphenol AF, bisphenol Z), 7 parabens (methyl-, ethyl-, propyl-, butyl-, benzyl-paraben, methyl-protocatechuic acid, and ethyl-protocatechuic acid), 5 benzophenones (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-8, and 4-hydroxybenzophenone), and two antimicrobials (triclosan and triclocarban) in human urine samples. Type and volume of solvent, extraction time (cycles), pH sample, ionic strength, agitation, and needle dimensions were evaluated. The matrix-matched calibration curves of all analytes were linear with correlation coefficients higher than 0.99 in the range level of 1.0-20.0 ng(-1). The relative standard deviation, precision, at three concentrations (1.0, 10.0 and 20.0 ng mL(-1)) was lower than 15% with accuracy ranging from 90% to 114%. The biomonitoring capability of the new proposed method was confirmed with the analysis of 50 human urine samples randomly collected from Brazilian children. High urinary concentrations of several EDCs associated with usage of personal care products were found. (AU)

Processo FAPESP: 13/23710-3 - Uso da espectroscopia Shpol'skii e LC-MS/MS para a determinação do bisfenol A e análogos em amostras de urina e avaliação da exposição em crianças residentes no estado de São Paulo
Beneficiário:Bruno Alves Rocha
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado