Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Elastic Properties of Lithium Disilicate Versus Feldspathic Inlays: Effect on the Bonding by 3D Finite Element Analysis

Texto completo
Autor(es):
Trindade, Flavia Zardo [1, 2] ; Valandro, Luiz Felipe [3] ; de Jager, Niek [4, 5] ; Bottino, Marco Antonio [2] ; Kleverlaan, Cornelis Johannes [4, 5]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Estadual Paulista, Araraquara Sch Dent, Dept Dent Mat & Prosthodont, Araraquara - Brazil
[2] Univ Estadual Paulista UNESP, ICT, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos - Brazil
[3] Univ Fed Santa Maria, Sch Dent, Dept Restorat Dent Prosthodont, Santa Maria, RS - Brazil
[4] Univ Amsterdam, Dept Dent Mat Sci, ACTA, Amsterdam - Netherlands
[5] Vrije Univ, Amsterdam - Netherlands
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY; v. 27, n. 8, p. 741-747, OCT 2018.
Citações Web of Science: 6
Resumo

PurposeTo determine the elastic properties of five ceramic systems with different compositions (lithium disilicate vs. feldspathic ceramics) and processing methods and compare the stress distribution in premolars in the interface with inlays made with these systems loaded with the maximum normal bite force (665 N) using 3D finite element analysis (FEA). Materials and MethodsThe elastic properties of five ceramic restoration materials (IPS e.max Press, IPS e.max CAD, Vita PM9, Vita Mark II, Vita VM7) were obtained using the ultrasonic pulse-echo method. Three-dimensional FEA simplified models of maxillary premolars restored with these ceramic materials were created. The models were loaded with a load at the two nodes on the occlusal surface in the middle of the tooth, 2 mm from the outside of the tooth, simulating a loading ball with a radius of 6 mm. ResultsThe means values of density (g/cm(3)), Young's modulus (GPa), and Poison's ratio was 2.6 0.3, 82.3 +/- 18.3, and 0.22 +/- 0.01 for IPS e.max Press; 2.3 +/- 0.1, 83.5 +/- 15.0, and 0.21 +/- 0.01 for IPS e.max CAD; 2.5 +/- 0.1, 44.4 +/- 11.5, and 0.26 +/- 0.08 for PM9; 2.4 +/- 0.1, 70.6 +/- 4.9, and 0.22 +/- 0.01 for Vitamark II; 2.4 +/- 0.1, 63.3 +/- 3.9, and 0.23 +/- 0.01 for VM7, respectively. The 3D FEA showed the tensile stress at the interface between the tooth and the inlay was dependent on the elastic properties of the materials, since the Vita PM9 and IPS e.max CAD ceramics presented the lowest and the highest stress concentration in the interface, respectively. ConclusionsThe elastic properties of ceramic materials were influenced by composition and processing methods, and these differences influenced the stress concentration at the bonding interface between tooth and restoration. The lower the elastic modulus of inlays, the lower is the stress concentration at the bonding interfaces. (AU)

Processo FAPESP: 10/51827-4 - Efeito da ciclagem mecânica em pré molares com inlays feitos de diferentes materiais cerâmicos na resistência de união dentina-restauração
Beneficiário:Luiz Felipe Valandro
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 10/07237-8 - Efeito da ciclagem mecânica em pré-molares com inlays feitos de diferentes materiais cerâmicos na resistência de união dentina-restauração
Beneficiário:Flávia Zardo Trindade
Modalidade de apoio: Bolsas no Brasil - Doutorado