Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Intrarater and Inter-rater Reliability of Maximal Voluntary Neck Muscle Strength Assessment Using a Handheld Dynamometer in Women With Headache and Healthy Women

Texto completo
Autor(es):
de Oliveira Camevalli, Ana Paula [1] ; Bevilaqua-Grossi, Debora [1] ; Sobral Oliveira, Ana Izabela [1] ; Carvalho, Gabriela Ferreira [1] ; Femandez-De-Las-Penas, Cesar [2] ; Lima Florencio, Lidiane [2]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Ribeirao Preto Med Sch, Dept Biomech Med & Locomotor Apparat Rehabil, Ave Bandeirantes 390X, BR-14049900 Ribeirao Preto, SP - Brazil
[2] Univ Rey Juan Carlos, Dept Phys Therapy Occupat Therapy Phys Med & Reha, Alcorcon - Spain
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS; v. 41, n. 7, p. 621-627, SEP 2018.
Citações Web of Science: 0
Resumo

Objective: This study aimed to determine the inter-rater and intrarater reliability, agreement, and minimal detectable change (MDC) of the neck muscle strength test using a handheld dynamometer in healthy women and women with headaches. Methods: Neck muscle strength in maximal voluntary contraction was measured using the Lafayette Manual Muscle Testing attached to a nonelastic belt in 25 women with migraines and in 25 healthy women. Three repetitions of flexion, extension, and lateral flexion were performed. The tests were performed by 2 examiners on the same day, with a 10-minute interval, and by 1 examiner, with a 1-week interval. The reliability was verified by the intraclass correlation coefficient, the agreement determined by standard error measurement, and the MDC calculated. Results: The protocol exhibited moderate to excellent intrarater and inter-rater reliabilities in both groups (intraclass correlation coefficient(range, ) 0.53-0.90). The standard error measurement ranged from 0.43 to 1.81 and the MDC from 1.49 up to 4.61. Conclusion: Quantification of neck muscle strength using the handheld dynamometer with an attached nonelastic belt exhibited moderate to excellent intra- and inter-rater reliability in women with and without migraines. Moreover, the standard error measurement and MDC were proven to be useful in the interpretation of data and in guiding clinical decisions. (AU)

Processo FAPESP: 15/15854-0 - Confiabilidade e concordância da avaliação da força voluntária máxima dos músculos cervicais pela dinamometria manual
Beneficiário:Ana Paula Oliveira Carnevalli de Miranda
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica