Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Performance of restricted access copper-imprinted poly(allylthiourea) in an on-line preconcentration and sample clean-up FIA-FAAS system for copper determination in milk samples

Texto completo
Autor(es):
Cajamarca Suquila, Fabio Antonio [1] ; Teixeira Tarley, Cesar Ricardo [1, 2]
Número total de Autores: 2
Afiliação do(s) autor(es):
[1] State Univ Londrina UEL, Dept Chem, Rodovia Celso Garcia Cid, PR 445, Km 380, BR-86050482 Londrina, PR - Brazil
[2] State Univ Campinas UNICAMP, Inst Chem, Dept Analyt Chem, Natl Inst Sci & Technol Bioanal INCTBio, CidadeUniv ZeferinoVaz S-N, BR-13083861 Campinas, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Talanta; v. 202, p. 460-468, SEP 1 2019.
Citações Web of Science: 0
Resumo

A new on-line solid phase preconcentration method using an ion-imprinted polymer with restrict access material based on copper-imprinted poly(allylthiourea) modified with 2-hydroxyethyl methacrylate and bovine serum (IIP-HEMA-BSA) to preconcentrate Cu2+ ions and exclude protein from milk samples via FIA-FAAS was developed. The samples were on-line preconcentrated at pH 4.5 through a mini-column packed with 50.0 mg of IIPHEMA-BSA at a flow rate of 7.6 mL min(-1) followed by a counter-current elution with 1.00 mol L-1 HCl towards the FAAS detector. The interference of ions commonly found in milk samples and the presence of BSA were investigated in the Cu2+ ions preconcentration. The method provided an analytical curve ranging from 3.6 to 100.0 mu g L-1, preconcentration factor of 24-fold, limit of detection of 1.1 mu g L-1 and sample throughput of 20 h(-1). The accuracy of the method was attested by Cu2+ ions addition/recovery tests as well as by using GFAAS of samples microwave-assisted digested. The proposed method was successfully applied to the copper determination in milk samples, requiring only pH adjustment followed by preconcentration step as sample pretreatment. Copper content in bovine milk sample was 0.635 +/- 0.042 mg kg(-1), while to soybean milk samples were between 0.048 +/- 0.008 and 0.094 +/- 0.005 mg kg(-1). To the best of our knowledge, the potential of IIP-HEMABSA for Cu2+ ions extraction from biological samples and simultaneous removal of macromolecules employing minimal sample pretreatment was demonstrated for the first time. The proposed extraction method stands out by being simple, fast and a low-cost analytical strategy when compared to the conventional microwave-assisted acid digestion. (AU)

Processo FAPESP: 14/50867-3 - INCT 2014: Instituto Nacional de Ciência e Tecnologia de Bioanalítica
Beneficiário:Marco Aurelio Zezzi Arruda
Modalidade de apoio: Auxílio à Pesquisa - Temático