Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Fractional anisotropy of the optic radiations correlates with the visual field after epilepsy surgery

Texto completo
Autor(es):
Ana Santos de Souza, Joao Paulo Sant [1] ; Ayub, Gabriel [2] ; Pereira, Pamela Castro [1] ; Cabral Vasconcellos, Jose Paulo [2] ; Yasuda, Clarissa [3, 1] ; Joaquim, Andrei Fernandes [3] ; Tedeschi, Helder [3] ; Campos, Brunno Machado [1] ; Cendes, Fernando [3, 1] ; Ghizoni, Enrico [3]
Número total de Autores: 10
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, UNICAMP, Neuroimaging Lab LNI, Rua Vital Brazil, 251 Cidade Univ Zeferino Vaz, BR-13083888 Campinas, SP - Brazil
[2] Univ Estadual Campinas, UNICAMP, Dept Ophthalmol, Rua Tessalia Vieira de Camargo 126, BR-13083887 Campinas, SP - Brazil
[3] Univ Estadual Campinas, UNICAMP, Dept Neurol & Neurosurg, Rua Tessalia Vieira de Camargo 126, BR-13083887 Campinas, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: NEURORADIOLOGY; v. 61, n. 12, p. 1425-1436, DEC 2019.
Citações Web of Science: 0
Resumo

Purpose This study assessed whether optic radiations (OR) microstructure after temporal lobe epilepsy (TLE) surgery correlated with visual field defects (VFD). Methods Patients were subjected to diffusion tensor imaging (DTI) tractography of the OR and Humphrey perimetry after TLE surgery. We used Spearman's test to verify correlations between tractographic parameters and perimetry mean deviation. Tractographic variables were compared between patients with VFD or intact perimetry. Multiple logistic regression was applied between DTI and perimetry values. DTI sensitivity and specificity were assessed with a receiver operating characteristic (ROC) curve to evaluate VFD. Results Thirty-nine patients had reliable perimetry and OR tractography. There was a significant correlation between (1) fractional anisotropy (FA) and both total (rho = 0.569, p = 0.0002) and quadrant (rho = 0.453, p = 0.0037) mean deviation and (2) radial diffusivity and total mean deviation (rho = - 0.350, p = 0.0286). There was no other significant correlation. Patients with VFD showed a significantly lower FA compared with patients with normal perimetry (p = 0.0055), and a 0.01 reduction in FA was associated with a 44% increase in presenting VFD after surgery (confidence interval, CI = 1.10-1.88; p = 0.0082). Using a FA of 0.457, DTI tractography showed a specificity of 95.2% and a sensitivity of 50% to detect VFD after surgery (area under the curve = 0.7619, CI = 0.6020-0.9218). Conclusion The postoperative OR microstructure correlated with visual loss after epilepsy surgery. DTI postoperative OR tractography may be helpful in evaluating VFD. (AU)

Processo FAPESP: 13/07559-3 - Instituto Brasileiro de Neurociência e Neurotecnologia - BRAINN
Beneficiário:Fernando Cendes
Modalidade de apoio: Auxílio à Pesquisa - Centros de Pesquisa, Inovação e Difusão - CEPIDs