Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Experimental self-etching resin infiltrants on the treatment of simulated carious white spot lesions

Texto completo
Autor(es):
Wang, Linda [1] ; Carvalho de Almendra Freitas, Maria Cristina [1, 2] ; Prakki, Anuradha [3] ; Mosquim, Victor [1] ; Miranda Gonzalez, Alejandra Hortencia [4] ; Rios, Daniela [5] ; Honorio, Heitor Marques [5]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Baum Sch Dent, Dept Operat Dent Endodont & Dent Mat, Bauru, SP - Brazil
[2] DeVry Educ Grp, DeVry FACID, Teresina, PI - Brazil
[3] Univ Toronto, Fac Dent, Restorat Dept, Toronto, ON - Canada
[4] Univ North Parana, Sch Dent, Dept Restorat Dent, Londrina, Parana - Brazil
[5] Univ Sao Paulo, Bauru Sch Dent, Dept Pediat Dent Orthodont & Publ Hlth, Bauru, SP - Brazil
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS; v. 113, JAN 2021.
Citações Web of Science: 0
Resumo

Objectives: To evaluate the penetration depth (mu m) of experimental resin infiltrants containing different percentages of triethylene glycol dimethacrylate (TEGDMA) and phosphoric acid 2-hydroxyethyl methacrylate ester (PAM) in artificial carious white spot lesions (WSL). Methods: WSL were produced in 65 bovine flat enamel specimens by pH cycling protocol, which were treated with either Icon (control) or experimental acidic infiltrants based on different percentages of TEGDMA and PAM monomers (acidic), and their association or not with previous acid-etching with phosphoric acid. Ten readings using Confocal Laser Scanning Microscopy were conducted on each specimen and the penetration depth was calculated from the surface until the deepest point with the fluorescent dye Rhodamine B (0.02 mg/mL). The pH and the viscosity of the experimental infiltrants were also tested. Data were statistically analyzed with two-way ANOVA and Tukey tests (alpha < 0.05). Results: The material factor and the interaction material{*}acid-etching were statistically significant. The lowest penetration depth was observed for the samples treated with the commercial infiltrant after etching with 15% hydrochloric acid. When specimens were pre-treated with PA, highest penetration was seen for specimens treated with 100% TEGDMA, which differed from all other groups. The lowest penetration was seen for those treated with 50:50 TEGDMA:PAM infiltrants. When specimens were not previously etched, highest penetration was seen for Icon, which differed only from those treated with 25% TEGDMA 75% PAM, where the lowest values were seen. The values of viscosity increased and the pH decreased with the addition of PAM in the infiltrant formulations. Conclusion: the association between TEGDMA and PAM seems to allow similar infiltration depth reached by Icon infiltrant without acid etching the enamel surface. (AU)

Processo FAPESP: 12/18579-2 - Efeito de um infiltrante resinoso no tratamento de lesões de mancha branca: análise in vitro, in situ e in vivo
Beneficiário:Maria Cristina Carvalho de Almendra Freitas
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 12/13160-3 - Efeito de adição de agente fluorescente (Rodamina B) a sistemas adesivos não simplificados: análise de propriedades físico-mecânicas
Beneficiário:Linda Wang
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 13/23310-5 - Avaliação da permeabilidade de infiltrantes resinosos experimentais no tratamento de lesões de mancha branca artificiais
Beneficiário:Maria Cristina Carvalho de Almendra Freitas
Modalidade de apoio: Bolsas no Exterior - Estágio de Pesquisa - Doutorado