Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Synthesis and performance of cross-linked poly (vinylpyridine-co-protoporphyrin) for effective cobalt determination using a micro-packed column hyphenated system coupled to FAAS

Texto completo
Autor(es):
de Almeida, Fernanda Garcia [1] ; Ferreira, Milena do Prado [1] ; Segatelli, Mariana Gava [1] ; Beal, Alexandra [1] ; Spinosa, Wilma Aparecida [2] ; Suquila Cajamarca, Fabio Antonio [1] ; Teixeira Tarley, Cesar Ricardo [1, 3]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] State Univ Londrina UEL, Dept Chem, Rod Celso Garcia Cid, PR 445 Km 380, Campus Univ, BR-86051990 Londrina, PR - Brazil
[2] State Univ Londrina UEL, Dept Food Sci & Technol, BR-86051990 Londrina, PR - Brazil
[3] State Univ Campinas UNICAMP, Natl Inst Sci & Technol Bioanalyt INCT, Inst Chem, Dept Analyt Chem, BR-13083970 Campinas, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: REACTIVE & FUNCTIONAL POLYMERS; v. 164, JUL 2021.
Citações Web of Science: 0
Resumo

The present study describes the development of a solid phase preconcentration method for cobalt determination at trace levels using cross-linked poly(vinylpyridine-co-protoporphyrin) as a highly efficient adsorbent and a hyphenated flow injection-FAAS system. The influence of molar amount of protoporphyrin and 4-vinylpyridine in the copolymer was studied aiming at obtaining the optimum synthesis condition in terms of adsorption capacity and swelling effect. The polymers were characterized by FT-IR, SEM, nitrogen adsorption/desorption, and swelling analyses. The method is based on cobalt preconcentration at pH 9.0 in 0.01 mol L-1 Tris/Tris-HCl buffer through the cylindrical mini-column packed with 50 mg of adsorbent at a flow rate of 7.4 mL min-1, whilst the elution was carried out by using 2.0 mol L-1 HNO3. Using the best synthesis conditions, the solid phase preconcentration method using poly(vinylpyridine-co-protoporphyrin) named poly(4VP-PP) (5.00 mmol of 4-vinylpyridine and 0.10 mmol of protoporphyrin) provided a linear range from 4.60-200.0 mu g L-1, the limit of detection of 1.38 mu g L-1, preconcentration factor of 38, consumption of index of 0.53 mL and analytical frequency of 22 h-1. Using the poly(4VP-PP), the method showed high selectivity for cobalt determination in the presence of concomitant ions, when compared to poly(4VP), thereby indicanting the great importance of protoporphyrin on the selective analytical performance of the method. The poly(4VP-PP) was successfully applied for the preconcentration of cobalt from different kind of samples without matrix interference, including dark chocolate powder, black tea, infusion of black tea, and water samples (mineral, tap, and lake waters), with high recovery results (91-104%). The feasibility of the method was also attested by analysis of certified reference material of marine sediment (MESS-3). (AU)

Processo FAPESP: 14/50867-3 - INCT 2014: Instituto Nacional de Ciência e Tecnologia de Bioanalítica
Beneficiário:Marco Aurelio Zezzi Arruda
Modalidade de apoio: Auxílio à Pesquisa - Temático