Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Electrochemical aptasensor for NS1 detection: Towards a fast dengue biosensor

Texto completo
Autor(es):
Bachour Junior, Bassam [1] ; Batistuti, Marina Ribeiro [1] ; Pereira, Aline Sanches [2] ; de Sousa Russo, Elisa Maria [2] ; Mulato, Marcelo [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Fac Philosophy Sci & Letters Ribeirao Preto, Dept Phys, Sao Paulo - Brazil
[2] Univ Sao Paulo, Sch Pharmaceut Sci Ribeirao Preto, Dept Clin Anal Toxicol & Food Sci, Sao Paulo - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Talanta; v. 233, OCT 1 2021.
Citações Web of Science: 2
Resumo

Dengue is one of the most commonly neglected tropical diseases transmitted by Aedes aegypti infected with Dengue virus. This virus belongs to the gender Flavivirus and produces a non-structural protein 1 (NS1), which is an important biomarker found at high levels in blood in early disease stage. Therefore, this study focused on the development of an electrochemical biosensor for NS1 detection using DNA aptamers. Gold electrodes were co-immobilized with specific aptamers and 6-mercapto-1-hexanol (MCH) to obtain a self-assembled monolayer. The molar ratio between aptamers and MCH was optimized and the platform characterized by electrochemical impedance spectroscopy and atomic force microscopy. Bovine serum albumin was added in NS1 solution to stabilize it and block the surface to avoid non-specific interactions. The biosensor performance was tested with NS1 protein serotype 4 (in phosphate saline buffer and human serum) and with a solution of serotype 1 in human serum. The results showed a sensitivity of 2.9%, 2.7% and 1.7% per decade, respectively, and low limit of detection (0.05, 0.022 and 0.025 ng/mL). The platform was also tested with Envelope protein as negative control. Furthermore, the aptamer sensor was able to detect NS1 in clinical range and it is a promising candidate for a new class for miniaturized point-of-care device for different Dengue serotypes. (AU)

Processo FAPESP: 13/26133-7 - Detecção de alterações relacionadas ao câncer de mama através de sensores de carga ou de massa acoplados a monocamadas de DNA
Beneficiário:Marina Ribeiro Batistuti Sawazaki
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 17/24201-6 - Plataformas Microeletrônicas para Biossensores Eletroquímicos, Piezoelétricos e FETs
Beneficiário:Marcelo Mulato
Modalidade de apoio: Auxílio à Pesquisa - Regular