Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Lithium Isotopic Ratios by Single-Collector ICP-SFMS: A Critical Evaluation Using Reference Materials

Texto completo
Autor(es):
Navarro, Margareth S. [1] ; Paula-Santos, Gustavo M. [2, 3, 1] ; Marteleto, Thais de P. [1] ; Enzweiler, Jacinta [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Campinas UNICAMP, Inst Geosci, Rua Carlos Gomes 250, BR-13083855 Campinas, SP - Brazil
[2] Univ Bremen, MARUM Ctr Marine Environm Sci, Leobener Str 8, D-28359 Bremen - Germany
[3] Univ Bremen, Fac Geosci, Leobener Str 8, D-28359 Bremen - Germany
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: GEOSTANDARDS AND GEOANALYTICAL RESEARCH; v. 45, n. 4 JUL 2021.
Citações Web of Science: 0
Resumo

We deployed a procedure to measure Li isotope ratios on a single-collector sector field inductively coupled plasma mass spectrometer (ICP-SFMS) operated with a desolvation system and a high-sensitivity skimmer cone. Under optimised instrumental acquisition conditions, chromatographically separated analyte solutions containing 1 ng g(-1) of Li provided adequate sensitivity using analogue mode detection for both isotopes, without adverse memory effect. Unprecedented for this isotopic system, we estimated the expanded uncertainty (U; k = 2) associated with the obtained delta Li-7 values to validate the procedure. Were considered as potential contributors to the combined uncertainty estimation (u(c)) the measurement intermediate precision, sample digestion and homogeneity, chromatographic separation, procedural blanks and homogeneity of the bracketing measurement standard (IRMM-016). The estimated U was on average (from results obtained with reference materials) 1.2 parts per thousand (k = 2). This is about twice the intermediate measurement precision (2s) of our data, highlighting the importance of evaluating other measurement uncertainty sources. The delta Li-7 values obtained for nineteen silicate rocks and one natural water agree with published values. We also provide the first delta Li-7 = (1.7 +/- 1.2; 0.7)parts per thousand (mean value +/- U (k = 2); intermediate precision (2s); n = 13) for basalt RM BRP-1. (AU)

Processo FAPESP: 19/14631-9 - Decifrando concentrações anômalas de urânio em água subterrânea
Beneficiário:Jacinta Enzweiler
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 16/06114-6 - O Sistema Terra e a evolução da vida durante o Neoproterozoico
Beneficiário:Ricardo Ivan Ferreira da Trindade
Modalidade de apoio: Auxílio à Pesquisa - Temático