Safety and structural integrity of N95/PFF2 respirators decontamination

Texto completo
Autor(es):
Coelho, Wanderson Eduardo Gomes de Souza [1] ; Perrechil, Fabiana [2] ; Pedreira, Mavilde L. G. [1] ; Lopes, Juliana Lima [1] ; Nurse, Maria Valdenice Lopes dos Santos [1] ; Gabrieloni, Maria Cristina [1] ; Perfeito, Joao Alessio [3] ; Moraes, Mariana Agostini de [2] ; Taminato, Monica [1]
Número total de Autores: 9
Afiliação do(s) autor(es):
[1] Univ Fed Sao Paulo, Escola Paulista Enfermagem, Rua Napoleao Barros, 754, Vila Clementino, BR-04024002 Sao Paulo, SP - Brazil
[2] Univ Fed Sao Paulo, Inst Ciencias Ambientais Quim Farmaceut, Dept Engenharia Quim, Sao Paulo - Brazil
[3] Univ Fed Sao Paulo, Escola Paulista Medicina, Sao Paulo - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: AMERICAN JOURNAL OF INFECTION CONTROL; v. 49, n. 10, p. 1221-1226, OCT 2021.
Citações Web of Science: 0
Resumo

Background: COVID-19 is caused by the SARS-CoV-2 virus, an emerging respiratory pathogen. The work environment represents a high-risk factor for health professionals. Given the scarcity of protective personal equipment due to global demand, decontamination and reuse studies should be carried out. Thus, the aim of this study was to evaluate the safety of a method of decontamination of N95/PFF2 respirators, especially regarding structural integrity. Methods: N95/PFF2 respirators were subjected to hydrogen peroxide decontamination and analyzed using scanning electron microscopy and thermogravimetric analysis. Seven respirators of the same brand and lot were used, one being a control and the other six subjected to decontamination process. As for the sealing, a qualitative test was applied, in order to identify the changes in the structure that could damage the sealing of respirators. Results: Indicated that the fiber morphology in all layers was not affected by the six decontamination cycles. Also, the thermal stability in the different layers was very similar. Fit testing showed that the respiradors submitted to all cycles of decontamination were approved. Conclusions: Thus, it is possible to conclude that the hydrogen peroxide decontamination method is effective, since it does not alter the physical properties of the respirators. (c) 2021 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved. (AU)

Processo FAPESP: 18/15539-6 - Sistemas biopoliméricos para co-encapsulação de compostos bioativos
Beneficiário:Fabiana Perrechil Bonsanto
Modalidade de apoio: Auxílio à Pesquisa - Regular