Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Intracranial compliance in type 2 diabetes mellitus and its relationship with the cardiovascular autonomic nervous control

Texto completo
Autor(es):
G.A.M. Galdino [1] ; S.C.G. Moura-Tonello [2] ; S.N. Linares [3] ; J.C. Milan-Mattos [4] ; D.L. Spavieri Jr. [5] ; S.M. Oliveira ; A. Porta ; T. Beltrame ; A.M. Catai [9]
Número total de Autores: 9
Afiliação do(s) autor(es):
[1] Universidade Federal de São Carlos. Departamento de Fisioterapia. Laboratório de Fisioterapia Cardiovascular - Brasil
[2] Universidade Federal de São Carlos. Departamento de Fisioterapia. Laboratório de Fisioterapia Cardiovascular - Brasil
[3] Universidade Federal de São Carlos. Departamento de Fisioterapia. Laboratório de Fisioterapia Cardiovascular - Brasil
[4] Universidade Federal de São Carlos. Departamento de Fisioterapia. Laboratório de Fisioterapia Cardiovascular - Brasil
[5] Divisão de Ciência de Dados, brain4care - Brasil
[9] Universidade Federal de São Carlos. Departamento de Fisioterapia. Laboratório de Fisioterapia Cardiovascular - Brasil
Número total de Afiliações: 9
Tipo de documento: Artigo Científico
Fonte: Brazilian Journal of Medical and Biological Research; v. 55, 2022-09-12.
Resumo

The intracranial compliance in type 2 diabetes mellitus (T2DM) patients and the association with cardiovascular autonomic control have not been fully elucidated. The aim of this study was to assess intracranial compliance using the noninvasive intracranial pressure (niICP) and the monitoring of waveform peaks (P1, P2, and P3) and the relationship with cardiovascular autonomic control in T2DM patients. Thirty-two men aged 40-60 years without cardiovascular autonomic neuropathy (CAN) were studied: T2DMG (n=16) and control group CG (n=16). The niICP was evaluated by a noninvasive extracranial sensor placed on the scalp. Cardiovascular autonomic control was evaluated by indices of the baroreflex sensitivity (BRS), from temporal series of R-R intervals of electrocardiogram and systolic arterial pressure, during supine and orthostatic positions. The participants remained in the supine position for 15 min and then 15 min more in orthostatism. T2DMG presented a decrease of the P2/P1 ratio during the orthostatic position (P<0.001). There was a negative moderate correlation between the P2 peak with cardiovascular coupling (K2HP-SAPLF) in supine (r=-0.612, P=0.011) and orthostatic (r=-0.568, P=0.020) positions in T2DMG. We concluded that T2DM patients without CAN and cardiovascular complications presented intracranial compliance similar to healthy subjects. Despite preserved intracranial adjustments, T2DM patients had a response of greater magnitude in orthostatism. In addition, the decoupling between the heart period and blood pressure signal oscillations in low frequency appeared to be related to the worsening of intracranial compliance due to the increased P2 peak. (AU)

Processo FAPESP: 17/09639-5 - Explorando técnicas de aprendizado de máquina para a modelagem do sistema aeróbio e suas aplicações em programas de reabilitação cardiorrespiratória
Beneficiário:Thomas Beltrame
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 10/52070-4 - Novas técnicas para avaliação das alterações das oscilações cardiovasculares com o envelhecimento
Beneficiário:Aparecida Maria Catai
Modalidade de apoio: Auxílio à Pesquisa - Regular