Busca avançada
Ano de início
Entree


Improving Accuracy in Inductively Coupled Plasma-Quadrupole Mass Spectrometry: The Interference Standard Method

Autor(es):
Donati, George L. ; Amais, Renata S. ; Nobrega, Joaquim A.
Número total de Autores: 3
Tipo de documento: Artigo Científico
Fonte: Spectroscopy; v. N/A, p. 4-pg., 2013-02-01.
Resumo

One of the main limitations with inductively coupled plasma mass spectrometry (ICP-MS) is related to the occurrence of spectral interferences. Considering the relatively low resolution presented by quadrupole-based mass spectrometry (ICP-QMS), sensitivity and accuracy can be compromised by interfering ions formed in the plasma. Several strategies have been proposed to overcome the problem, and the most successful ones are based on high-resolution instruments, mixed-gas plasmas, or collision-reaction cells and interfaces. A different approach was recently proposed based on the idea that interfering polyatomic ions and some plasma naturally occurring Ar species present similar behaviors. The so-called interference standard method (IFS) uses the analytical to IFS signal ratio associated with external calibration to minimize the interfering species contribution to the analytical signal, thereby improving ICP-QMS accuracy. In this work, the efficiency of the IFS method in the determination of Si is evaluated. A 130% recovery was found for Si-28 determined in a standard reference material (Typical Diet, NIST 1848a) using the conventional external calibration method without any interference correction. Such high recovery is a result of spectral interferences caused by molecular ions such as N-2(+) and (CO+)-C-12-O-16. On the other hand, no statistically significant difference at a 95% confidence level was found between reference- and IFS-determined values using the (ArH+)-Ar-36 or Ar-38(+) probes. Limits of detection of 6.0, 5.0, and 8.0 mu g/L were calculated for determinations at m/z 28 or using the 28/37 and 28/38 signal ratios, respectively. Possible mechanisms responsible for the IFS method efficiency also are discussed here. (AU)

Processo FAPESP: 10/50238-5 - Determinacao de fosforo, enxofre e silicio em biodiesel usando espectrometro de massa acoplado ao plasma induzido com interface de colisao e reacao
Beneficiário:George Luis Donati
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 10/17387-7 - Avaliação de técnicas espectroanalíticas e procedimentos de preparo de amostras para a determinação de enxofre em biodiesel e misturas com diesel
Beneficiário:Renata Stábile Amais
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 06/59083-9 - Espectrometria de massa acoplada ao plasma induzido: aspectos fundamentais e aplicações
Beneficiário:Joaquim de Araújo Nóbrega
Modalidade de apoio: Auxílio à Pesquisa - Temático