Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Real-time quantitative PCR in cerebral toxoplasmosis diagnosis of Brazilian human immunodeficiency virus-infected patients

Texto completo
Autor(es):
Mesquita, Rafael T. [1] ; Ziegler, Angela P. [2] ; Hiramoto, Roberto M. [1] ; Vidal, Jose E. [2, 3] ; Pereira-Chioccola, Vera L. [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Inst Adolfo Lutz Registro, Parasitol Lab, Sao Paulo - Brazil
[2] Inst Infectol Emilio Ribas, Dept Neurol, Sao Paulo - Brazil
[3] Univ Sao Paulo, Fac Med, Hosp Clin, Serv Extensao Atendimento Pacientes HIV, Div Molestias Infecciosas & Parasitarias, Sao Paulo - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Journal of Medical Microbiology; v. 59, n. 6, p. 641-647, JUN 2010.
Citações Web of Science: 33
Resumo

Cerebral toxoplasmosis is the most common cerebral mass lesion in AIDS patients in Brazil, and results in high mortality and morbidity, despite free access to HAART (highly active antiretroviral treatment). Molecular diagnosis based on conventional PCR (cnPCR) or real-time quantitative PCR (qrtPCR) has been indispensable for definitive diagnosis. We report here the evaluation of qrtPCR with blood and cerebrospinal fluid (CSF) samples from AIDS patients in Brazil. This prospective study was conducted for 2 years, analysing DNA samples extracted from 149 AIDS patients (98 blood and 51 CSF samples) with confirmed clinical and radiological diagnosis The laboratory diagnosis included cnPCR (with the B22/B23 primer set) and indirect immunofluorescence (IF). For qrtPCR, two primer sets were simultaneously designed based on described genes and using a 6-carboxyfluorescein dye-labelled TaqMan MGB (minor groove binder) probe One was Bug, which amplified a sequence from the B1 gene The other was the RETg, which amplified a PCR product of the 529 bp sequence. The overall cnPCR and qrtPCR results were positive results were observed in 33.6% (50) patients The sensitivities were 98% for cnPCR (B22/B23), and 86 and 98% for qrtPCR (B1Tg and RETg, respectively). Negative reactions were observed in 66 4% patients. The specificities were 97% for cnPCR and qrtPCR (B1Tg). and 88.8% for RETg These data show that RETg PCR is highly sensitive as it amplifies a repeat region with many copies; however, its specificity is lower than the other markers However, B1Tg PCR had good specificity, but lower sensitivity Among the patients, 20 had blood and CSF collected simultaneously Thus, their results permitted us to analyse and compare molecular, serological and clinical diagnosis for a better understanding of the different scenarios of laboratorial and clinical diagnosis. For nine patients with confirmed cerebral toxoplasmosis diagnosis, four scenarios were observed: (i) and (ii) negative molecular diagnosis for CSF and positive for blood with variable IF titres for the sera and CSF (negative or positive), (iii) positive molecular diagnosis with CSF and negative with blood, and (iv) positive molecular diagnosis in both samples. In the latter two situations, normally the IF titres in sera and CSF are variable. Other opportunistic infections were shown in 11 patients Despite the IF titres in sera and CSF being variable, all of them had negative molecular diagnosis for both samples qrtPCR allows for a rapid identification of Toxoplasma gondii DNA in patient samples; in a minority of cases discrepancies occur with the cnPCR. (AU)

Processo FAPESP: 08/09311-0 - Diagnóstico laboratorial da toxoplasmose com enfoque nas infecções congênita e cerebral
Beneficiário:Vera Lúcia Pereira Chioccola
Modalidade de apoio: Auxílio à Pesquisa - Regular