Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

The performance of conventional and fluorescence-based methods for occlusal caries detection An in vivo study with histologic validation

Texto completo
Autor(es):
Diniz, Michele B. [1, 2] ; Boldieri, Thalita [1] ; Rodrigues, Jonas A. [3] ; Santos-Pinto, Lourdes [1] ; Lussi, Adrian [4] ; Cordeiro, Rita C. L. [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] UNESP Univ Estadual Paulista, Sch Dent Araraquara, Dept Pediat Dent, Sao Paulo - Brazil
[2] Cruzeiro Sul Univ UNICSUL, Sch Dent, Dept Pediat Dent, BR-04110060 Sao Paulo - Brazil
[3] Univ Fed Rio Grande do Sul, Sch Dent, Dept Pediat Dent, Porto Alegre, RS - Brazil
[4] Univ Bern, Sch Dent Med, Dept Prevent Restorat & Pediat Dent, CH-3012 Bern - Switzerland
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF THE AMERICAN DENTAL ASSOCIATION; v. 143, n. 4, p. 339-350, APR 2012.
Citações Web of Science: 38
Resumo

Background. The authors conducted an in vivo study to determine clinical cutoffs for a laser fluorescence (LF) device, an LF pen and a fluorescence camera (FC), as well as to evaluate the clinical performance of these methods and conventional methods in detecting occlusal caries in permanent teeth by using the histologic gold standard for total validation of the sample. Methods. One trained examiner assessed 105 occlusal surfaces by using the LF device, LF pen, FC, International Caries Detection and Assessment System (ICDAS) criteria and bitewing (BW) radiographic methods. After tooth extraction, the authors assessed the teeth histologically. They determined the optimal clinical cutoffs by means of receiver operating characteristic curve analysis. Results. The specificities and sensitivities for enamel and dentin caries detection versus only dentin caries detection thresholds were 0.60 and 0.93 and 0.77 and 0.52 (ICDAS), 1.00 and 0.29 and 0.97 and 0.44 (BW radiography), 1.00 and 0.85 and 0.77 and 0.81 (LF device), 0.80 and 0.89 and 0.71 and 0.85 (LF pen) and 0.80 and 0.74 and 0.49 and 0.85 (FC), respectively. The accuracy values were higher for ICDAS, the LF device and the LF pen than they were for BW radiography and the FC. Conclusions. The clinical cutoffs for sound teeth, enamel carious lesions and dentin carious lesions were, respectively, 0 through 4, 5 through 27 and 28 through 99 (LF device); 0 through 4, 5 through 32 and 33 through 99 (LF pen); and 0 through 1.2, 1.3 and 1.4 through 5.0 (FC). The ICDAS, the LF device and the LF pen demonstrated good performance in helping detect occlusal caries in vivo. The ICDAS did not seem to perform as well at the D, threshold (histologic scores 3 and 4) as at the D-3 threshold (histologic scores 1-4). BW radiography and the FC had the lowest performances in helping detect lesions at the D-1 and Da thresholds, respectively. Clinical Implications. Occlusal caries detection should be based primarily on visual inspection. Fluorescence-based methods may be used to provide a second opinion in clinical practice. (AU)

Processo FAPESP: 09/00218-0 - Avaliação do desempenho de métodos baseados em indução de fluorescência na detecção de lesões de cárie: estudos in vitro e in vivo
Beneficiário:Rita de Cássia Loiola Cordeiro
Modalidade de apoio: Auxílio à Pesquisa - Regular