Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Microchip electrophoresis with amperometric detection for the study of the generation of nitric oxide by NONOate salts

Texto completo
Autor(es):
Gunasekara, Dulan B. [1, 2] ; Hulvey, Matthew K. [1, 3] ; Lunte, Susan M. [1, 2, 4] ; Fracassi da Silva, Jose Alberto [5, 1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Kansas, Ralph N Adams Inst Bioanalyt Chem, Lawrence, KS 66045 - USA
[2] Univ Kansas, Dept Chem, Lawrence, KS 66045 - USA
[3] Akermin Inc, St Louis, MO 63134 - USA
[4] Univ Kansas, Dept Pharmaceut Chem, Lawrence, KS 66045 - USA
[5] Univ Estadual Campinas, Inst Quim, BR-13083000 Campinas, SP - Brazil
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: ANALYTICAL AND BIOANALYTICAL CHEMISTRY; v. 403, n. 8, p. 2377-2384, JUN 2012.
Citações Web of Science: 16
Resumo

Microchip electrophoresis (ME) with electrochemical detection was used to monitor nitric oxide (NO) production from diethylammonium (Z)-1-(N,N-diethylamino)diazen-1-ium-1,2-diolate (DEA/NO) and 1-(hydroxyl-NNO-azoxy)-l-proline disodium salt (PROLI/NO). NO was generated through acid hydrolysis of these NONOate salts. The products of acid hydrolysis were introduced into a 5-cm separation channel using gated injection. The separation was accomplished using reverse polarity and a background electrolyte consisting of 10 mM boric acid and 2 mM tetradecyltrimethylammonium bromide, pH 11. Electrochemical detection was performed using an isolated potentiostat in an in-channel configuration. Potentials applied to the working electrode, typically higher than +1.0 V vs. Ag/AgCl, allowed the direct detection of nitrite, NO, DEA/NO, and PROLI/NO. Baseline resolution was achieved for the separation of PROLI/NO and NO while resolution between DEA/NO and NO was poor (1.0 +/- 0.2). Nitrite was present in all samples tested. (AU)

Processo FAPESP: 10/01046-6 - Desenvolvimento de dispositivos microfluídicos com detecção eletroquímica para análise de espécies reativas de nitrogênio em células isoladas in vitro
Beneficiário:José Alberto Fracassi da Silva
Modalidade de apoio: Bolsas no Exterior - Pesquisa
Processo FAPESP: 08/57805-2 - Instituto de Bioanalítica
Beneficiário:Lauro Tatsuo Kubota
Modalidade de apoio: Auxílio à Pesquisa - Temático
Processo FAPESP: 08/53868-0 - Síntese e caracterização de novos materiais estrategicamente estruturados e organizados para aplicações em dispositivos analíticos e fotônicos
Beneficiário:Lauro Tatsuo Kubota
Modalidade de apoio: Auxílio à Pesquisa - Temático