Clinical and microbiological evaluation of high intensity diode laser adjutant to non-surgical periodontal treatment: a 6-month clinical trial

Texto completo
Autor(es):
Euzebio Alves, Vanessa Tubero [1] ; Pinto de Andrade, Ana Karina [1] ; Toaliar, Janaita Maria [1] ; Conde, Marina Clemente [1] ; Zezell, Denise Maria [2] ; Cai, Silvana [3] ; Pannuti, Claudio Mendes [1] ; De Micheli, Giorgio [1]
Número total de Autores: 8
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Discipline Periodont, BR-05508900 Sao Paulo - Brazil
[2] IPEN CNEN SP, Ctr Lasers & Applicat, Lab Biophoton, BR-05508900 Sao Paulo - Brazil
[3] Univ Sao Paulo, Inst Biomed Sci, Dept Microbiol, BR-05508900 Sao Paulo - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: CLINICAL ORAL INVESTIGATIONS; v. 17, n. 1, p. 87-95, JAN 2013.
Citações Web of Science: 18
Resumo

This randomized split-mouth clinical trial was designed to evaluate the efficacy of scaling and root planing associated to the high-intensity diode laser on periodontal therapy by means of clinical parameters and microbial reduction. A total of 36 chronic periodontitis subjects, of both genders, were selected. One pair of contralateral single-rooted teeth with pocket depth > 5 mm was chosen from each subject. All patients received non-surgical periodontal treatment, after which the experimental teeth were designated to either test or control groups. Both teeth received scaling, root planing and coronal polishing (SRP) and teeth assigned to the test group (SRP + DL) were irradiated with the 808 +/- 5 nm diode laser, for 20 s, in two isolated appointments, 1 week apart. The laser was used in the continuous mode, with 1.5 W and power density of 1,193.7 W/cm(2). Clinical and microbiological data were collected at baseline, 6 weeks and 6 months after therapy. There was a significant improvement of all the clinical parameters-clinical attachment level (CAL), probing depth (PD), plaque index (PI) and Bleeding on Probing (BOP)-for both groups (P < 0.001), with no statistical difference between them at the 6 weeks and the 6 months examinations. As for microbiological analysis, a significant reduction after 6 weeks (P > 0.05) was observed as far as colony forming units (CFU) is concerned, for both groups. As for black-pigmented bacteria, a significant reduction was observed in both groups after 6 months. However, the difference between test and control groups was not significant. There was no association between group and presence of Porphyromonas gingivalis, Prevotella intermedia and Aggregatibacter actinomycetemcomitans at any time of the study. After 6 months of evaluation, the high-intensity diode laser has not shown any additional benefits to the conventional periodontal treatment. The high intensity diode laser did not provide additional benefits to non-surgical periodontal treatment. More studies are necessary to prove the actual need of this type of laser in the periodontal clinical practice. (AU)

Processo FAPESP: 05/56965-8 - Avaliacao dos parametros clinicos e microbiologicos apos raspagem associada ou nao ao uso do laser de diodo de alta intensidade (808nm+/-5nm) em bolsas periodontais de dentes unirradiculares.