Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Aluminum concentrations in central and peripheral areas of malignant breast lesions do not differ from those in normal breast tissues

Texto completo
Autor(es):
Rodrigues-Peres, Raquel Mary [1] ; Cadore, Solange [2] ; Febraio, Stefanny [2] ; Heinrich, Juliana Karina [1] ; Serra, Katia Piton [1] ; Derchain, Sophie F. M. [1] ; Vassallo, Jose [3] ; Sarian, Luis Otavio [1]
Número total de Autores: 8
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Fac Med Sci, Dept Obstet & Gynecol, Campinas, SP - Brazil
[2] Univ Estadual Campinas, Inst Chem, Dept Analyt Chem, Campinas, SP - Brazil
[3] Univ Estadual Campinas, Fac Med Sci, Dept Pathol, Campinas, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: BMC CANCER; v. 13, MAR 8 2013.
Citações Web of Science: 9
Resumo

Background: Aluminum is used in a wide range of applications and is a potential environmental hazard. The known genotoxic effects of aluminum might play a role in the development of breast cancer. However, the data currently available on the subject are not sufficient to establish a causal relationship between aluminum exposure and the augmented risk of developing breast cancer. To achieve maximum sensitivity and specificity in the determination of aluminum levels, we have developed a detection protocol using graphite furnace atomic absorption spectrometry (GFAAS). The objective of the present study was to compare the aluminum levels in the central and peripheral areas of breast carcinomas with those in the adjacent normal breast tissues, and to identify patient and/or tumor characteristics associated with these aluminum levels. Methods: A total of 176 patients with breast cancer were included in the study. Samples from the central and peripheral areas of their tumors were obtained, as well as from the surrounding normal breast tissue. Aluminum quantification was performed using GFAAS. Results: The average (mean +/- SD) aluminum concentrations were as follows: central area, 1.88 +/- 3.60 mg/kg; peripheral area, 2.10 +/- 5.67 mg/kg; and normal area, 1.68 +/- 11.1 mg/kg. Overall and two-by-two comparisons of the aluminum concentrations in these areas indicated no significant differences. We detected a positive relationship between aluminum levels in the peripheral areas of the tumors, age and menopausal status of the patients (P = .02). Conclusions: Using a sensitive quantification technique we detected similar aluminum concentrations in the central and peripheral regions of breast tumors, and in normal tissues. In addition, we did not detect significant differences in aluminum concentrations as related to the location of the breast tumor within the breast, or to other relevant tumor features such as stage, size and steroid receptor status. The next logical step is the assessment of whether the aluminum concentration is related to the key genomic abnormalities associated with breast carcinogenesis. (AU)

Processo FAPESP: 08/02469-8 - Instabilidade genômica em neoplasias malignas da mama em função da presença do receptor de estrógeno e da concentração de alumínio intracelular
Beneficiário:Luís Otávio Zanatta Sarian
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 09/06148-4 - Instabilidade genômica em neoplasias malignas da mama em função da presença do receptor de estrógeno e da concentração de alumínio intracelular
Beneficiário:Raquel Mary Rodrigues Peres
Modalidade de apoio: Bolsas no Brasil - Doutorado